Send Message
Home ProductsVortex Flow Meter

LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer

LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer

  • LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer
  • LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer
LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer
Product Details:
Place of Origin: China (Mainland)
Brand Name: Kacise
Model Number: LC
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time: 5-8 working days
Payment Terms: L/C, T/T, Western Union, MoneyGram, D/A, D/P
Supply Ability: 10000pcs/month
Contact Now
Detailed Product Description
Accuracy: 0.5 Grade, 0.2 Grade Product Name: Oval Gear Flowmeter
Method Of Intallation: Horizoontal, Vertical Shell Material: Cast Iron, Cast Steel, Stainless Steel
Connecting Method: Flange Name: Oval Gear Type Flow Meter
High Light:

compressed air flow meter

,

insertion type flow meter

Series Oval Gear Flow Meter Oval positive displacement flow meter with strainer for bitumen
 
Introduction
 

Oval gear flowmeters are highly precise instruments used for the continuous measurement of liquid flow in pipelines. They offer various advantages, including a wide measuring range, low pressure loss, adaptability to high viscosity, the capability to measure high-temperature liquids, convenient calibration, and easy installation. As representative products in the positive displacement flowmeter category, oval gear flowmeters play a crucial role in accurately measuring liquid flows.

 

The LC series oval gear flowmeter is equipped with an on-site pointer display and a word wheel cumulative counting device. This configuration allows for the direct display of the cumulative flow of liquid passing through the pipeline. Specifically designed for metering refined oil products, it is extensively employed in industries such as petroleum, chemicals, chemical fiber, transportation, commerce, food, medicine, health, and more. It facilitates precise flow measurement of non-corrosive media in diverse applications.

 

Usage
 
LC-A type cast iron oval gear flow meter, widely used in all kinds of oil products and for the measurement of the cast iron material not corrosion liquid medium.
LC-E type cast steel oval gear flow meter, Used for high pressure, low corrosive medium measurement.
LC-Q type cast iron oval gear flow meter, The rotor for aluminum alloy, is suitable for low viscosity, low corrosion, such as gasoline, etc.) the measurement of liquid medium.
LC-B, C type stainless steel oval gear flow meter, widely used in strong corrosive liquid medium, such as acid, alkali, salt and organic compounds, the measurement of liquid medium.
LC-L type Aluminum alloy oval gear flow meter, is a small oval gear flow meter, widely used in low corrosive liquid medium, such as water, such as the measurement of liquid medium.

 

Materials of main parts and the nominal operating pressure

  Shell and cover cover plate oval wheel Rotary shaft bushing Nominal pressure(MPa)
LC-A Cast steel Cast iron

Cast iron,Stainless steel

Alloy aluminum,

engineering material

Stainless steel Bronze(with oil) or rolling bearing 1.6
LC-E Cast steel Cast iron

Under DN50 6.3

DN80-100 4.0 6.3

DN150-200 2.5

LC-B,C Stainless steel Stainless steel Stainless steel graphite,rolling bearing 1.6,2.5

Notes:1. 0Cr18Ni12Mo2Ti for type LC-C; 0Cr18Ni9Ti for type LC-B.

2. Flange is convex under 2.5MPa ,and roughness at 6.3 MPa;and both of the above at 4.0 MPa.

2. Accuracy class class 0.5,class 0.2

3. Operating temperature: series LC-A(-20℃~+60℃),series LC-B,E,L(-41℃~+60℃)

60℃~200℃(with high temp. radiator installed)

4  Explosion-proof mark: ExiaⅡCT5, dⅡBT4

5. Flow range: unit: m3/h

Type DN Viscosity (mPa. s)

<0.3

  •  

0.3~0.8

  •  
0.8~2 2~200

200~1000

 

1000~2000

 

 

 

 

 

LC-10

10

 

 

 

0.2-0.5

 

  0.08-0.5 0.08-0.5

0.05-0.5

 

0.06-0.3

0.03-0.3

 

0.03-0.2

 

 

LC-15

15

 

 

 

0.75-1.

5

  0.3-1.5 0.3-1.5

0.15-1.5

0.3-3

0.2-1.0

0.1-1.05

 

0.07-0.75

 

 

 

LC-20

20

 

 

 

1.5-3

 

1-3 0.5-3 0.5-3

0.3-3

1.5-15

0.4-2.1

0.2-2.1

 

0.15-1.5

 

 

 

LC-25

25

 

4-6

 

3-6

 

2-6 1-6 1-6

0.6-6

1.56-15

0.8-4.2

0.4-4.2

 

0.3-3

 

 

 

LC-40

40

 

9-15

 

7.5-15

 

5-15 2.5-15 2.5-15

1.5-15

 

2.1-10.5

1.0-10.5

 

0.7-7.5

 

 

LC-50

50

 

10-24

 

8-24

 

8-24 4.8-24 4.8-24

2.4-24

 

2.4-16.8

1.6-16.8

 

1.2-12

 

 

 

LC-B40,50 40,50 8-20 6-20 6-20 4-20 4-20 2-20 2.8-14 1.4-14 1.0-10
LC--65

65

 

27-40

 

20-40

 

15-40 8-40 8-40

4-40

 

5.6-28

2.8-28

 

2-20

 

 

 

LC-80

80

 

40-60

 

30-60

 

20-60 12-60 12-60

6-60

 

8.4-42

4.2-42

 

3-30

 

LC-100

100

 

67-100

 

50-100

 

34-100 20-100 20-100

10-100

 

14-70

6-70

 

5-50

 

LC-150

150

 

127-190

95-190

 

 

 

 

64-190 38-190 38-190

19-190

 

26.6-133

13.3-133

 

9.5-95

 

LC-200 200 227-340

170-340

 

114-340 56-340 56-340

34-340

 

47.6-238

23.8-238

 

17-170

 

Accuracy class   0.5 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.5
 

Note: If the temperature of the metered liquid is higher than 80℃. the maximum flow fate will be 90% of the primary flow, and the minimum will be 120%.

 

Installation and Operation

  • A strainer should be installed in front of the meter, and be sure that the arrows on the casting of the meter and the strainer pointing the same direction of the liquid flow.
  • If the metered media contains gas, a gas separator should be installed in front of the meter.
  • Whether the pipe line is vertically or horizontally installed, the wheel’s shaft of the meter must be fixed horizontal, that is, the dial is vertical to the surface.
  • While the meter is installed properly, the counter may be turned 180°or 90°for easy reading.
  • Prior to the installation of the new meter, first push the oval wheels from the outlet for several times with a bamboo rod, if the wheels don’t move, they can be immersed in the petrol to prevent from deposits in the meter after the factory’s inspection.
  • A throttle valve must be fixed at the inlet of the meter, an on-off valve at the outlet, which must be slowly activated to prevent from a sudden impact, reverse flow, and water hammer.
  • It is forbidden to clean the meter with steam.
  • For the continuous operated departments, a by-pass should be mounted.
  • Prior to the installation of the meter, the pipe line must be thoroughly cleaned,and at the time of cleaning use a straight pipeline in stead of the meter,to prevent impurity,welding residue from entering the meter.
  • It is forbidden to inspect the meter made of cast iron and cast steel using water.
  • During the operated of the meter the flow rate can’t exceed the flow marked on the mamelon plate. It is preferable to operate the meter at 50—80% of the max. flow.
  • If the metered media is causticity,stainless steel shall be selected.

LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer 0LC Series Oval Gear Type Flow Meter Oval Positive Displacement Flow Meter With Strainer 1

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Other Products

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.