Send Message
Home ProductsTurbine Flow Meter

Stainless Steel Turbine Water Flow Meter Sanitary Flow Meter Flange Connection

Stainless Steel Turbine Water Flow Meter Sanitary Flow Meter Flange Connection

  • Stainless Steel Turbine Water Flow Meter Sanitary Flow Meter Flange Connection
Stainless Steel Turbine Water Flow Meter Sanitary Flow Meter Flange Connection
Product Details:
Place of Origin: China (Mainland)
Brand Name: Kacise
Model Number: KXTUF
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time: 5-8 working days
Payment Terms: L/C, T/T, Western Union, MoneyGram, D/A, D/P
Supply Ability: 10000pcs/month
Contact Now
Detailed Product Description
Accuracy: 0.5 Grade, 0.2 Grade,1 Grade Product Name: Turbine Flow Meter
Range Ratio: 1:15, 1:20, 1:10 Sensor Mateiral: 304, 316(L) Stainless Steel Etc.
Connecting Method: Flange Power Supply: +12V DC, +24V DC (optional)
Medium Temp.: -20~120 Protection: IP65
High Light:

turbine water flow meter

,

diesel fuel flow meter

DN50mm small LWGY Pulse output digital Modbus RS485 liquid water turbine flowmeter for measuring liquid

 

Description

 

KXTUF turbine flow meter is the use of advanced low-power single-chip microprocessor technology developed turbine flow sensor and display totalizer integration of new smart meter, with a compact structure, intuitive readings clear, high reliability, without outside power interference, anti-lightning, obvious low cost advantage, it is widely used to measure the closed pipe and stainless steel 1Cr18Ni9Ti, 2Cr13 and corundum Al2O3, carbide not corrode, and no fibers, particles and other impurities, kinematic viscosity at operating temperature is less than 5 × 10-6m² / s of liquid, for kinematic viscosity more than 5 × 10-6m² / s of liquid, can be quantitative control, excessive alarm, etc., is an ideal flow metering and energy meter.

Measurement objects: oil, organic liquids, inorganic liquid, liquefied petroleum gas, natural gas, coal gas and cryogenic fluids.

 

Turbine flow metera flow meter that widely applied in industries of pharmaceutical, food, beverage for measurement, batching, control, filling, etc. Rotating part of the flow meter is made of special material that possesses good anti-corrosive and rust proof performance. Structure of the flow meter is special designed and greatly approved accuracy and repeatability of the flow meter. Product also with easy maintenance connection, which is suitable for pharmaceutical and beverage industries.

 

Features

☆ High accuracy, generally up to ±1%R, ±0.5%R, high accuracy up to 0.2%R
☆ Good repeat-ability, short-term repeat-ability up to 0.05% ~ 0.2%, in the trade settlement is the preferred choice of flow meter.
☆ Output of pulse frequency signal, suitable for totalizer and connection with PC; no zero shift and strong interference resist
☆ High frequency signal(3~4KHz) can be obtained, the signal resolution is strong.
☆ Wide range, medium and large diameter up to 1:20, small caliber 1:10.
☆ Compact structure & convenient maintenance

 

Specifications

 

Paremeter Value Unit

 

Diameter

Thread 4, 6, 10, 15, 20, 25, 32, 40 mm
Flange(Clamp) 15, 20, 25, 32, 40, 50, 65, 80, 100, 125,150, 200 mm
Accuracy ±1, ±0.5, ±0.2 (customized) %R
Range ratio 1:10, 1:15, 1:20  
Sensor material 304, 316(L) stainless steel etc.  

 

Working

environment

Medium temp. -20~120 °C
Ambient temp -10~55 °C
Relative humidity 5%~90%  
Atmospheric pressure 86~106 KPa
Signal output

Sensor: pulse frequency signal, low electrical level≤0.8V, high level≥8V

Transmitter: two wire, 4-20 mA DC current signal

 
Comm interface RS485  

 

Power supply

 

Sensor: +12V DC, +24V DC (optional)

Transmitter: +24V DC

Local indication type: built-in 3V lithium cell or +24VDC external

 
Signal Transmission Wire STVPV3×0.3 (3 wire), 2×0.3 (2 wire)  
Transmission Distance No more than 1000 m
Signal Line Interface

Basic type: Hausman connector or 3-core wire;

Explosion-proof type: M20 × 1.5 (F)

 
Explosive-proof grade

Basic type: non-explosion proof;

explosion proof type: ExdIIBT6

 
Protection level IP65  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stainless Steel Turbine Water Flow Meter Sanitary Flow Meter Flange Connection 0

 

Measuring Range & Working Pressure

 

Diameter

(mm)

Standard Range (m3/h) Extended Range (m3/h)

Normal Connection &

Pressure Rating (MPa)

Special Pressure Rating (MPa) (Flange Connection)
DN4 0.04~0.25 0.04~0.4 Thread connection/6.3 10, 16, 25
DN6 0.1~0.6 0.06~0.6 Thread connection/6.3 10, 16, 25
DN10 0.2~1.2 0.15~1.5 Thread connection/6.3 10, 16, 25
DN15 0.6~6 0.4~8 Thread connection/6.3 4.0, 6.3, 10, 16, 25
Flange connection/2.5
DN20 0.8~8 0.45~9 Thread connection/6.3 4.0, 6.3, 10, 16, 25
Flange connection/2.5
DN25 1~10 0.5~10 Thread connection/6.3 4.0, 6.3, 10, 16, 25
Flange connection/2.5
DN32 1.5~15 0.8~15 Thread connection/6.3 4.0, 6.3, 10, 16, 25
Flange connection/2.5
DN40 2~20 1~20 Thread connection/6.3 4.0, 6.3, 10, 16, 25
Flange connection/2.5
DN50 4~40 2~40 Flange connection/2.5 4.0, 6.3, 10, 16, 25
DN65 7~70 4~70 Flange connection/2.5 4.0, 6.3, 10, 16, 25
DN80 10~100 5~100 Flange connection/2.5 4.0, 6.3, 10, 16, 25
DN100 20~200 10~200 Flange connection/2.5 4.0, 6.3, 10, 16, 25
DN125 25~250 13~250 Flange connection/1.6 2.5, 4.0, 6.3, 10, 16
DN150 30~300 15~300 Flange connection/1.6 2.5, 4.0, 6.3, 10, 16
DN200 80~800 40~800 Flange connection/1.6 2.5, 4.0, 6.3, 10, 16

 

Dimension

Stainless Steel Turbine Water Flow Meter Sanitary Flow Meter Flange Connection 1

Diagram 1 (DN4~DN10): Threaded connection type turbine flow sensor (including straight pipe section).

Diagram 2 (DN15~DN40): Thread connected flow sensor size drawing.

Diagram 3 (DN4~DN10): Flange connected turbine flow sensor drawing.

Sensor installation method according to different specifications, Adopt thread or flange connection, the installation method is shown in diagram 1, 2, 3

 

Installation dimensions

 

Diameter(mm) L(mm) G K(mm) D(mm) n(hole)
4 295 G1/2      
6 330 G1/2      
10 450 G1/2      
15 75 G1 Φ65 Φ14 4
20 80 G1 Φ75 Φ14 4
25 100 G5/4 Φ85 Φ14 4
32 140 G2 Φ100 Φ14 4
40 140 G2 Φ110 Φ18 4
50 150   Φ125 Φ18 4
65 170   Φ145 Φ18 4
80 200   Φ160 Φ18 8
100 220   Φ180 Φ18 8
125 250   Φ210 Φ18 8
150 300   Φ240 Φ22 8
200 360   Φ295 Φ22 12

 

Ordering information

 

Model Remarks
KTF                
DN 4             4 mm
6             6 mm
10             10 mm
15             15 mm
20             20 mm
25             25 mm
32             32 mm
40             40 mm
50             50 mm
65             65 mm
80             80 mm
100             100 mm
125             125 mm
150             150 mm
200             200 mm
Type N           Sensor type: +12V or 24V power, output 3 wire system pulse signal
A           Transmitter type: +24V power, output 2 wire 4-20 mA
B           Smart type: lithium cell, local indicator, without signal output
C           Smart type: +24V power, local indicator, 2 wire 4-20mA/pulse output
C1           Smart type: +24V power, local indicator, RS485 communication
            protocol
C2           Smart type: +24V power, local indicator, HART protocol
Accuracy 05         0.5
10         1.0
02         0.2 (Special order, long delivery time)
Range W       Extended Measuring Range
S       Standard Measuring Range
Body Material S     304 SS
L     316 (L) SS
Explosion Proof N   Non Explosion proof
E   Explosion proof, ExdIIBT6
Pressure Rating N Normal
H (x) High Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Other Products

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.