Send Message
Home ProductsUltrasonic Transducer Sensor

KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor

KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor

  • KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor
  • KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor
  • KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor
  • KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor
KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor
Product Details:
Place of Origin: China
Brand Name: Kacise
Model Number: KUS3000 M30-Type1
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: 15*20*15cm,0.3kg
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100+
Contact Now
Detailed Product Description
Range: 2m Protection Class: IP65
Material: Nickel-plated Copper Supports Customization Blind Spot: 200mm
Half Power Angle: 10° Temperature: -25~70℃
Precision: ≤1 % Resolution: 0.1mm
High Light:

KUS3000 Ultrasonic Transducer Sensor

,

Ultrasonic Transducer Sensor For Distance

,

KUS3000 Level Proximity Sensor

KUS3000 M30-Type1 Ultrasonic Level Meter

KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor 0
 

1. Dimensional structure

The unit is mm.
KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor 1
2. Electrical interface

Note: This product has two cable specifications, and the cable wiring instructions of the two specifications are as follows:

Type A cable Type B cable
Pin1 Brown Pin1 Yellow
Pin2 White Pin2 Black
Pin3 Blue Pin3 Red
Pin4 Black Pin4 Green

 

The default cable mix is based on the specifications received by the customer

3. Technical parameter

M30-type 1
Range 200... 2000 mm
Adjustable interval range 200….2000mm
Blind spot 0 ... 200 mm
Response time approx. 10 ms


Indicator light

Blue led light The blue light flashes to indicate that calibration can be performed. Blue and other constants indicate that the power supply of the sensor is normal. The blue light will flash within 5 minutes after the power is turned on, indicating that the user can perform output adjustment and calibration. After 5 minutes, the blue light is always on to indicate that the sensor cannot be receiving Calibration command. .
Tellow led light It is used to indicate whether the measured object is detected. During the calibration stage, the yellow light flashes to indicate that the current calibration state is locked, and it can be switched to the next calibration state.
Red LED light

In normal working state, the red light is not on, and the red light is on to indicate that there is a fault.

During the calibration process, the flashing red light indicates that the sensor locks the current echo loss or infinity state, and the user can switch to the next calibration state.

 

Electrical parameters

Supply voltage 13 ... 30 V DC , Special wide voltage requirements can be customized
No-load current I0 ≤ 45 mA

 

IOT-spectric models

Supply voltage 3.3-12 DC , ripple 10 %SS
Power consumption I0 ≤ 15 mA, sleep mode≤1mA, Serial wake up,

 

Output

Output type

1 Switch output PNP output normally open and long closed can be calibrated

2 Switch output NPN output normally open and long closed programmable

3 Analog voltage output 0-10V programmable.

4 Analog 4-20mA output programmable

5 RS485 output E4 programmable.

Overcurrent Ie 200 mA , Reverse polarity protection, short circuit protection
Default setting

M18 Switch point A1: 150mm Switch point A2: 1000mm

M30 Type 1 switch point A1 200mm switch point A2: 2000mm

M30 type 2 switch point A1 300mm switch point A2: 4000mm

M30 type 3 switch point A1 500mm switch point A2: 6000mm

Output voltage drop ≤ 2.5 V
Repeatability ≤1 %
On-off level f ≤ 13 Hz High frequency can be customized
Default hysteresis characteristic amplitude 5% of the set value, special requirements can be customized
Temperature Compensation Range -40℃-85℃

 

Temperature Requirements

Working temperature -25…70℃(248...343K)
Storage temperature -40…85℃(233...358K)

 

Mechanical part description

Even machine V1 connector(M12×1),4-Pin
Protection class IP65 Other can be customized
Shell material Nickel-plated copper, others can be customized

Note: When the M18 product and M30 product have 4-20mA analog output, the meter connection method is different from that of the 550,600 product. Since the output terminal of the M18 and M30 products is powered by VDD, as shown in Figure 1, the meter should be connected to the power supply port. Between the output terminal and the output terminal, the connection instruction diagram is shown in Figure 2:

KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor 2
        Figure 1 Output power supply circuit diagram

 

 

 

KUS3000 M30-Type1 high repeatability, small and compact housing ultrasonic proximity sensor 3
 

Figure 2 Schematic diagram of connection method

 

4. Sensor function description

Switch point and advance interval setting and adjustment of switch output and analog output products

Switch value and analog output can be set using the adjustment terminal, specifically, there are 8 working modes that can be set.

The specific setting method of each type of bean flour is the following steps.

In the first step, the user selects a distance set by himself, or puts the sensor into a lost wave state.

The second part, connect the calibration terminal to the power supply or GND, keep it connected until the yellow light flashes (if the wave is lost, the red light flashes).

In the third step, the user selects the second distance set by himself, or lets the sensor enter the lost wave state.

The fourth step, connect the calibration terminal to GND or power supply (the state is different from the second step), keep it connected until the yellow light flashes (if the wave is lost, the red light flashes).

There are 8 working modes of switch output

1. Window normally open mode (analog output products are in positive linear working mode or distance measurement mode).

2. Window normally closed mode (analog output product is in negative linear working mode or liquid level measurement mode).

3. Single point normally open mode.

4. Single point normally closed mode.

5. Single-point normally open mode with large hysteresis interval.

6. Single point normally closed with large hysteresis interval mode.

7. Whether to detect the normally open mode.

8. Whether to detect normally closed mode.

Description of RS485 output model products.

There are 3 working modes,

1: Automatic measurement mode, the sensor continuously measures the liquid level and distance, and the user can read the measurement results through the 485 interface at any time.

2: If the user does not initiate a 485 communication, the sensor will initiate a measurement and report the result.

3: Sleep mode, the product enters sleep mode, the user first wakes up the sensor through the 485 interface, and then initiates a measurement and obtains the result before the sensor sleeps again.

Definition of LED indicator meaning
    When calibrating During normal work
red light Bright error indication error indication
extinguish normal work normal work
flicker Indicates the status of the calibration station lock-on echo loss meaningless
Yellow light Bright ---- detected object
extinguish ------ The measured object is lost
flicker Instructs the calibration stage to lock the current position and can switch to the next calibration state The echo lost and echo detected states alternate. relatively critical.
Blue light Bright normal power supply normal power supply
extinguish Abnormal power supply Abnormal power supply
flicker Indicates that the user can calibrate the sensor at the current time meaningless

 

5. Installation conditions

When installing, pay attention to protect the surface of the sensor to avoid injury. If you work in an environment with heavy volatile gas or dust and heavy condensation, you need to clean the surface of the sensor regularly to avoid sensitivity reduction or failure to work. The installation thread should not be over-tightened, which will cause the sensor to be pressurized and not work properly.

6. Order information

KUS

 

Types of Output Range Describe
  M18 M18 housing, maximum measuring range is 1 meter
M30-Type1 M30 maximum measuring range is 2 meter
M30-Type2 M30 maximum measuring range is 3 meter
M30-Type3 M30 maximum measuring range is 6 meter, 8 meters can be customized
Customized Shell supports user customization
  NPN output as NPN
PNP output as PNP
10Vout The output is analog 0-10V, the power supply requirement is greater than 11V
5Vout The output is analog 0-5V, the power supply requirement is greater than 6V
mAout The output is analog 4-20mA
RS485 The output is RS485 Modbus protocol, please refer to the software interface manual for specific description.
    XXX mm The customer specifies the linear interval or switch interval, which can be set at the factory
KUS M30 RS485 2000mm  

 

 

 

 


 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.