Place of Origin:
China (Mainland)
Brand Name:
Kacise
Certification:
certificate of explosion-proof, CE
Model Number:
KLD800
KLD800 series 80G radar level gauge adopts frequency modulated continuous wave (FMCW) technology. The antenna emits a high-frequency FM radar signal, and the frequency of the radar signal increases linearly. The transmitted radar signal is received by the same antenna after being reflected by the measured medium. At the same time, the frequency difference between the transmitted signal frequency and the received signal frequency is proportional to the measured distance. The collected frequency difference signal is subjected to fast Fourier transform (FFT) to obtain the spectrum of the reflected echo, and the distance to the target to be measured is calculated based on this.
KLD801 |
Medium: liquid, non-corrosive Measuring range: 0.05m~10/20/30/60/100m Process connection: G1½A / 1½NPT thread / flange ≥ DN40 Process temperature: -40~80℃ Process pressure: -0.1~0.3 MPa Antenna size: 32mm lens antenna Antenna material: PTFE Accuracy: ±1mm Protection class: IP67 Center frequency: 80GHz Launch angle: 8° Power supply: two-wire /DC24V four-wire /DC12~24V four-wire /AC220V Casing: aluminum/stainless steel Signal output: two-wire /4...20mA/HART protocol four-wire / 4...20mA/ RS485 Modbus |
KLD802
|
Medium: non-corrosive liquid, slightly corrosive liquid Measuring range: 0.1m~10/20/30/60/100m Process connection: flange ≥ DN80 Process temperature: -40~110℃ Process pressure: -0.1~1.6MPa Antenna size: 32mm lens antenna Antenna material: PTFE Accuracy: ±1mm Protection class: IP67 Center frequency: 80GHz Launch angle: 8° Power supply: two-wire /DC24V four-wire /DC12~24V four-wire /AC220V Casing: aluminum/stainless steel Signal output: two-wire /4...20mA/HART protocol four-wire / 4...20mA/ RS485 Modbus |
KLD803
|
Medium: strong corrosive liquid, steam, foam Measuring range: 0.1m~10/20/30/60/100m Process connection: flange ≥ DN50 Process temperature: -40~130℃ Process pressure: -0.1~2.5MPa Antenna size: 34mm lens antenna (according to flange size) Antenna material: PTFE Accuracy: ±1mm Protection class: IP67 Center frequency: 80GHz Launch angle: 8° Power supply: two-wire /DC24V four-wire /DC12~24V four-wire /AC220V Casing: aluminum/stainless steel Signal output: two-wire /4...20mA/HART protocol four-wire 4...20mA/ RS485 Modbus |
KLD804
|
Medium: non-corrosive liquid, slightly corrosive liquid Measuring range: 0.1m~10/20/30/60/100m Process connection: flange ≥ DN50 Process temperature: -40~130℃ Process pressure: -0.1~1.0MPa Antenna size: 76mm lens antenna Antenna material: PTFE Accuracy: ±1mm Protection class: IP67 Center frequency: 80GHz Launch angle: 3° Power supply: two-wire /DC24V four-wire /DC12~24V four-wire /AC220V Casing: aluminum/plastic/stainless steel Signal output: two-wire /4...20mA/HART protocol four-wire 4...20mA/ RS485 Modbus |
KLD805
|
Medium: strong corrosive liquid, steam, foam, high temperature. and high pressure Measuring range: 0.1m~10/20/30/60/100m Process connection: flange ≥ DN80 Process temperature: -40~200℃ Process pressure: -0.1~2.5MPa Antenna size: 76mm lens antenna (according to flange size) Antenna material: PTFE/overall filling Accuracy: ±1mm Protection class: IP67 Center frequency: 80GHz Launch angle: 3° Power supply: two-wire /DC24V four-wire /DC12~24V four-wire /AC220V Casing: aluminum / plastic / stainless steel Signal output: two-wire /4...20mA/HART protocol four-wire 4...20mA/ RS485 Modbus |
KLD806 |
Medium: solid, storage container, process container, strong dust application Measuring range: 0.3m~10/20/30/60/100m Process connection: flange ≥ DN100 Process temperature: -40~110℃ Process pressure: -0.1~0.3MPa Antenna size: 76mm lens antenna (purge optional) Antenna material: PTFE Accuracy: ±1mm Protection class: IP67 Center frequency: 80GHz Launch angle: 3° Power supply: two-wire /DC24V four-wire /DC12~24V four-wire /AC220V Casing: aluminum/plastic/stainless steel Signal output: two-wire /4...20mA/HART protocol four-wire 4...20mA/ RS485 Modbus |
Send your inquiry directly to us