Detailed Product Description
Measuring Range: 0~14pH Resolution: 0.01pH
Accuracy: ±0.1pH Working Temperature: 0~65℃
Working Pressure: <0.2MPa Temperature Compensation: Auto Temperature Compensation (NTC)
High Light:

Dual High Impedance online ph sensor

,

14pH Measuring online ph sensor

,

RS-485 online ph monitoring system

KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol) Dual High-Impedance Differential Amplifier

1.Application Environment

Used for environmental water quality monitoring, acid/alkali/salt solution, chemical reaction process and industrial production process, it can meet the requirements of online pH measurement for most industrial applications.
 

2.Feature

  • Signal output: RS-485 (Modbus/RTU protocol).
  • Convenient connection to third-party devices such as PLCs, DCS, industrial control computers, general-purpose controllers, paperless recording instruments or touch screens.
  • Dual high-impedance differential amplifier with strong anti-interference and fast response.
  • The patented pH probe, the internal reference solution oozes extremely slowly from the microporous salt bridge at a pressure of at least 100 kpa (1 Bar), and its forward bleed continues for more than 20 months. Such a reference system is very stable and the electrode life is extended by a factor of two compared to conventional industrial electrodes.
  • Easy to install: 3/4 NPT pipe thread for easy submersible installation or installation in pipes and tanks.
  • IP68 protection grade.

2.Technical Specifications

Model KPH601
Measuring Range 0~14pH
Resolution 0.01pH
Accuracy ±0.1pH
Working Temperature 0~65℃
Working Pressure <0.2MPa
Temperature Compensation Auto temperature compensation (NTC)
Power Supply 12~24VDC ±10%
Signal Output RS-485(Modbus/RTU)
Wetted Material POM
Mounting Method Immersion mounting, 3/4 NPT thread
Cable Length 5 meters, other lengths can be customized
Calibration Two-point calibration
Power Consumption <0.3W@12V
Protection Grade IP68
 

3.Dimensional Drawing

Dual High Impedance KPH601 Online PH Sensor Output RS-485 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:The sensor connector is M16-5 core waterproof joint male head.

4.Installation and Electrical Connection

4.1 Installation

Dual High Impedance KPH601 Online PH Sensor Output RS-485 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The sensor should not be installed upside down or horizontally when installed, at least at an angle of 15 degrees or more.

4.2 Electrical Connection

a) Red line - power cord (12 ~ 24V)
b) Black line - ground (GND)
c) Blue line - 485A
d) white line - 485B
e) bare wire - shielded wire
After wiring is completed, it should be carefully checked to avoid incorrect connections before powering up.

Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air, the cable has certain corrosion resistance. The outer diameter of the cable is Φ6 mm and all interfaces are waterproof.

5.Maintenance

5.1 Use and Maintenance

When measuring the pH sensor, it should be cleaned in distilled water (or deionized water), and the filter paper should be used to absorb moisture to prevent impurities from being introduced into the liquid to be tested. 1/3 of the sensor should be inserted into the solution to be tested.
The sensor should be washed when not in use, inserted into a protective sleeve with a 3.5 mol/L potassium chloride solution, or the sensor inserted into a container with a 3.5 mol/L potassium chloride solution.
Check if the terminal is dry. If it is stained, wipe it with absolute alcohol and dry it. Avoid long-term immersion in distilled water or protein solution and prevent contact with silicone grease. With a longer sensor, its glass film may become translucent or with deposits, which can be washed with dilute hydrochloric acid and rinsed with water. The sensor is used for a long time. When a measurement error occurs, it must be calibrated with the meter for calibration.
When the calibration and measurement cannot be performed while the sensor is being maintained and maintained in the above manner, the sensor has failed. Please replace the sensor.

 

                                                    Standard Buffer pH Reference Table

 

 

Dual High Impedance KPH601 Online PH Sensor Output RS-485 2
The actual reading and standard of the instrument sometimes have an error of ±1 word.

5.2 Calibration

Note: The sensor has been calibrated before leaving the factory. If the measurement error is not exceeded, it should not be arbitrarily calibrated.
a) Zero Calibration
Use 250 mL of distilled water in a measuring cylinder, pour into a beaker, add a packet of calibration powder with pH=6.86, stir evenly with a glass rod until the powder is completely dissolved, configure the solution with pH=6.86, put the sensor into the solution, wait for 3 ~5 minutes, after the value is stable, see if the displayed value is 6.86. If not, you need to perform zero calibration. Refer to the appendix for the calibration instructions.
 
b) Slope Calibration
For acidic solution: Take 250 mL of distilled water in a measuring cylinder, pour into a beaker, add a packet of calibration powder with pH=4.00, stir evenly with a glass rod until the powder is completely dissolved, and configure the solution to pH=4.00; In the solution, wait for 3 to 5 minutes. After the value is stable, see if the value is 4.00. If not, the slope calibration is required. Refer to the appendix for the calibration instructions.
For alkaline solution: Take 250 mL of distilled water in a measuring cylinder, pour into a beaker, add a packet of calibration powder with pH=9.18, stir evenly with a glass rod until the powder is completely dissolved, and configure the solution to pH=9.18; In the solution, wait for 3 to 5 minutes. After the value is stable, check if the display is 9.18. If not, the slope calibration is required. Refer to the appendix for the calibration instructions.

6.Quality and Service

6.1 Quality Assurance

  • The quality inspection department has standardized inspection procedures, advanced and perfect testing equipment and means, and strictly in accordance with the regulations, to do 72-hour aging test and stability test on the product, and not to allow one unqualified product to leave the factory.
  • The receiving party directly returns the product batch with a failure rate of 2%, and all the costs incurred are borne by the supplier. The reference standard refers to the product description provided by the supplier.
  • Guarantee the quantity of goods and the speed of shipment.

6.2 Accessories and Spare Parts
This product includes:

  • 1 sensor
  • Calibration powder 3 packs
  • 1 copy of the manual
  • 1 certificate

6.3 After-sales Service Commitment
The company provides local after-sales service within one year from the date of sale, but does not include damage caused by improper use. If repair or adjustment is required, please return it, but the shipping cost must be conceited. Damaged on the way, the company will repair the damage of the instrument for free.
 
 

Contact Us

Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
 
Dual High Impedance KPH601 Online PH Sensor Output RS-485 3
 
 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.