Home ProductsUltrasonic Flow Meter

High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter

High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter

  • High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter
  • High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter
High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter
Product Details:
Place of Origin: China
Brand Name: KACISE
Certification: CE
Model Number: KUFS2000C
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: Negotiable
Packaging Details: one carton for one set
Delivery Time: 5-8 work days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Contact Now
Detailed Product Description
Pipe Diameter: DN32-6000mm Liquid Type: Single Liquid Can Transmit Sound Wave, Such As Water, Sewage, Oil, Chemicals, Plant Effluent, Beverage, Ultra-pure Liquids, Etc.
Temperature: -30℃~160℃ Power Supply: 220Vac / 24Vdc
Pipe Material: Steel, Stainless Steel, Cast Iron, Copper, Cement Pipe, PVC, Aluminum, Glass Steel Product, Liner Is Allowed. Output Signal: 4-20mA, Pulse, Relay
Digital Communication: RS485 Certificate: Explosion Proof
High Light:

portable clamp on flow meter

,

ultrasonic liquid flow meter

Metal Casing Explosion Proof Wall Type Ultrasonic Flow Meter For for Explosive and Combustible Conditions

 

Introduction

 

KUF2000 series ultrasonic flow meter usually is used in long-term measurement at field. It has three types of sensor to measure the pipe flow: clamp on type, insertion type and inline pipe type. KUFS2000C Explosion Proof Ultrasonic Flow Meter is designed for Explosive and Combustible Conditions. It can measure flow, also can measure heat if contact temperature sensor. SD card is optional for large quantity data storage.


Insertion type: Only two installation holes are needed on the pipe, user can install the insertion type sensors. By using the hole making tool, the no stop flow installation can be realized. Sensors contact to the fluid directly, the measurement is stable and reliable.

Clamp on type: The sensors clamp on to the outside of pipes and do not come in contact with the internal liquid. And all the models can become energy meters when connecting to temperature sensors. KUF2000 Series Clamp On Ultrasonic Flowmeter is easy for installation, no need to cut off the pipe and water, no press loss. It support measuring online long-term. Wide range of liquid flow can be measured with the sensor clamped on the pipe.
Inline pipe type: DN15-32 pipes uses π shape inline pipe sensor, DN40 and above uses standard inline pipe sensor. The inline sensors has the advantages of low starting flow rate, high measurement accuracy and no pressure loss.

 

Parameters

 

Item Performance and Parameter

 

 

 

 

 

 

 

Host part

Principle Ultrasonic time gap
Accuracy ±1%
Display 2×20 character LCD with backlight, support the language of Chinese, English and Italy Convertor dimension:170*180*56cm

 

Signal output

1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0. 1%
1 way OCT pulse output( Pulse width 6 ~ 1 0 0 0 ms,default is 2 0 0 ms)
1 way Relay output

 

Signal input

3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as temperature, press and liquid level
Connect the temperature transducer Pt100, can finish the heat/energy measurement
Data interface Insulate RS485 serial interface, upgrade the flow meter software by computer, support the MODBUS, METER-BUS etc.
Cable

Twisted-pair cable, generally, the length under 50 meters;

Select the RS485 communication. The transmission distance can over 1000m.

 

 

Pipe Condition

Pipe material Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed.
Pipe Diameter 15~6000mm
Straight length pipe Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump.

 

Measuring Medium

Type of Liquid Water, sea water, waste water, oil, chemicals (alcohol, acids, etc.), plant effluent and other liquids
Temperature -30~160℃
Turbidity 10000pm not so much baubles
Flow speed 0~±10m/s

 

Environment

Temperature Host: -20~60℃; Sensor: -30~160℃
Humidity Host: 85%RH; Flow sensor: IP68, less than 2m under water
Power supply DC8~36V or AC85~265V( optional)
consumption 1.5W

 

High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter 0

 

Sensor Selection

 

High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter 1

 

Optional Temp. sensor

 

High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter 2

Ordering Information

 

High Accuracy Explosion Proof Flow Meter , Wall Type Ultrasonic Liquid Flow Meter 3

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Evelyn

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.