KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

  • KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen
  • KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen
KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen
Product Details:
Place of Origin: CHINA
Brand Name: kacise
Certification: CE
Model Number: KFDO310
Payment & Shipping Terms:
Minimum Order Quantity: 0-100
Price: $0-$2000
Packaging Details: Common package or custom package
Delivery Time: 3-10days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100
Contact Now
Detailed Product Description
Measuring Principle: Fluorescence Range: 0ー20 Mg/L (0ー200% Saturation, 25 °C)
Resolution: 0.01 Mg/l, 0.1 °C Precision: ± 2% F.s. , ± 0.5 °C
Temperature Compensation: Automatic Temperature Compensation (PT1000) Output Mode: RS-485 Bus, Modbus-RTU Protocol

1.Principle

KFDO310 integrated on-line fluorescence dissolved oxygen sensor is designed and made based on the quenching principle of excited fluorescence of specific substances in physics. The blue light from the light-emitting diode illuminates the fluorescent material on the inner surface of the fluorescent cap. The fluorescent material on the inner surface is excited and emits red light. By detecting the phase difference between the red light and the blue light, and comparing it with the internal calibration value, the concentration of oxygen molecule can be calculated, and the final value can be output by temperature automatic compensation.

2.Feature

No electrolytes, no polarization

No need to consume oxygen, not affected by the flow rate

Built-in temperature sensor, automatic temperature compensation

Free from chemicals like sulfides

Small drift, fast response, more accurate measurement

Maintenance-free, long service life, lower use cost

Fluorescent caps are easy to replace

RS-485 interface, Modbus-RTU protocol

3.Technical Specifications

Model number KFDO310
Measuring principle fluorescence
Range 0ー20 mg/L (0ー200% saturation, 25 °C)
Resolution 0.01 mg/l, 0.1 °C
Precision ± 2% f.s. , ± 0.5 °C
Temperature compensation Automatic temperature compensation (PT1000)
Output mode RS-485 bus, Modbus-RTU protocol
Working conditions 0ー45 °C, < 0.2 mpa
Storage temperature - 5 ~ 65 °C
Installation mode Immersion mounting
Cable length 5 meters, other length can be customized
Power consumption < 0.05 W
Power supply 12 ~ 24 VDC ± 10%
Protection level IP68
Calibration Two-point calibration
Fluorescent cap life Guaranteed Use for one year (under normal use)
Material for sensor housing Pom and 316L stainless steel
 

4.Dimensional Drawing

 

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 0

 

 

 

 

5.Installation and Electrical Connection

Installs

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 1

The temperature sensing part should be immersed below the liquid surface to avoid collision with the film head surface. The head part of the membrane should be free from sediment.

 

How Can Water be More than 100% Saturated?

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 2

Henry’s law determining the dissolved oxygen concentration at 20 degrees C and 100% air saturation (1 kg water = 1 L water)

100% air saturation is the equilibrium point for gases in water. This is because gas molecules diffuse between the atmosphere and the water’s surface. According to Henry’s Law, the dissolved oxygen content of water is proportional to the percent of oxygen (partial pressure) in the air above it 13. As oxygen in the atmosphere is about 20.3%, the partial pressure of oxygen at sea level (1 atm) is 0.203 atm. Thus the amount of dissolved oxygen at 100% saturation at sea level at 20° C is 9.03 mg/L ¹⁰.

The equation shows that water will remain at 100% air saturation at equilibrium. However, there are several factors that can affect this. Aquatic respiration and decomposition lower DO concentrations, while rapid aeration and photosynthesis can contribute to supersaturation. During the process of photosynthesis, oxygen is produced as a waste product. This adds to the dissolved oxygen concentration in the water, potentially bringing it above 100% saturation ¹⁴. In addition, the equalization of water is a slow process (except in highly agitated or aerated situations). This means that dissolved oxygen levels can easily be more than 100% air saturation during the day in photosynthetically active bodies of water ¹⁴.

 

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 3

Dissolved oxygen often reaches over 100% air saturation due to photosynthesis activity during

the day

 

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 4

Supersaturation of water can be caused by rapid aeration from a dam.

Supersaturation caused by rapid aeration is often seen beside hydro-power dams and large waterfalls. Unlike small rapids and waves, the water flowing over a dam or waterfall traps and carries air with it, which is then plunged into the water. At greater depths and thus greater hydrostatic pressures, this entrained air is forced into solution, potentially raising saturation levels over 100%.

Rapid temperature changes can also create DO readings greater than 100%. As water temperature rises, oxygen solubility decreases. On a cool summer night, a lake’s temperature might be 60° F. At 100% air saturation, this lake’s dissolved oxygen levels would be at 9.66 mg/L. When the sun rises and warms up the lake to 70° F, 100% air saturation should equate to 8.68 mg/L DO. But if there is no wind to move the equilibration along, the lake will still contain that initial 9.66 mg/L DO, an air saturation of 111%.

 

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.