Send Message
Home ProductsWater Quality Sensor

KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference

KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference

  • KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference
  • KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference
  • KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference
  • KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference
KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference
Product Details:
Place of Origin: China
Brand Name: Kacise
Model Number: KWS-600
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: carton
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100+
Contact Now
Detailed Product Description
Range: 0-20mg/L Or 0-200% Saturation Accuracy: ±1%
Response Time: 10 Sec Ip Grade: IP68
Sensor Drift: <1% Per Year Operating Temperature: 0~50℃
Temperature Accuracy: ±0.2℃ Output: RS485, Modbus
Power Supply: DC6-12V ±5%, Current<50mA Temperature Sensor: NTC
Casing Diameter: 26mm Casing Length: 177.5mm
Cable Length: Standard 10m, Customizable 5m, 15m And 30m Fluorescent Cap Lifetime: 1 Year (under Normal Use)
Casing Material: POM And Stainless Steel
High Light:

Stainless Steel Dissolved Oxygen Sensor

,

No Interference Dissolved Oxygen Sensor

,

Dissolved Oxygen Water Quality Sensor

KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference 0

1. Feature
Kacise dissolved oxygen sensor support RS485/Modbus communication. Optional automatic cleaning brush to eliminate the impact of oil on the measurement, this product uses a unique optical and electronic filtering technology to eliminate the impact of ambient light on the measurement, not affected by suspended solids.

  • Best-in-class fluorescence lifetime technology and high performance fluorescent materials.
  • No oxygen consumption, no flow rate restrictions, no electrolyte, no maintenance and calibration required, no hydrogen sulphide interference, excellent stability.
  • Built-in temperature sensor with automatic temperature compensation.
  • RS485 output for networking without controller.

2. Application
The fluorescence dissolved oxygen sensor uses a new generation of fluorescence lifetime technology. Kacise independently develops high performance fluorescent materials. No anaerobic consumption, no flow restrictions, no electricity required. The solution requires no maintenance and calibration, no hydrogen sulphide, and excellent stability. Built-in temperature sensor and automatic temperature compensation. The RS485 output is suitable for networks without a controller.
3.Technical Specifications

 

Range 0-20mg/L or 0-200% saturation
Accuracy ±1%
Response Time 10 sec
Ip Grade IP68
Sensor Drift <1% per year
Operating Temperature 0~50℃
Temperature Accuracy ±0.2℃
Output RS485, Modbus
Power Supply DC6-12V ±5%, current<50mA
Temperature Sensor NTC
Casing Diameter 26mm
Casing Length 177.5mm
Cable Length Standard 10m, customizable 5m, 15m and 30m
Fluorescent Cap Lifetime 1 year (under normal use)
Casing Material POM and stainless steel
Dimensions
KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference 1
Packaging
KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference 2

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.