Product Details
Measured Components:
CO, CO₂, CH₄, C₃H₈, O₂, H₂S
Measurement Principle:
NDIR, ECD
Measurement Range:
CO/CO₂/CH₄/C₃H₈: (0 - 100)%; O₂: (0 - 25)%; H₂S: (0 - 9999) Ppm
Linearity Error:
CO/CO₂/CH₄/C₃H₈: ±1%F.S.; O₂/H₂S: ±2%F.S.
Highlight:

Industrial Site Safety Infrared Gas Analyzer

,

Explosion - Proof Infrared Gas Analyzer

,

Infrared Gas Analyzer KGD - MQ - 510

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
Explosion-Proof Infrared Gas Analyzer KGD-MQ-510 For Industrial Site Safety
The Explosion-Proof Infrared Gas Analyzer KGD-MQ-510 adopts non-dispersive infrared (NDIR) gas analysis technology and long-life electrochemical sensing technology with independent intellectual property rights. It can simultaneously measure the volume concentrations of gases such as CO, CO₂, CH₄, C₃H₈, O₂, and H₂S online.
Explosion - Proof Infrared Gas Analyzer KGD - MQ - 510 For Industrial Site Safety 0
Key Features
  • Explosion-Proof Design: Flame-proof enclosure withstands explosion pressure and prevents flame transmission, meeting safety requirements for flammable environments.
  • High Measurement Accuracy: No cross-interference among measured gases with self-diagnosis function for sensor status monitoring.
  • Stable Performance: Dual-channel sensor design with heat-resistant and corrosion-resistant materials (stainless steel, PTFE) for gas contact parts.
  • Automated Operation: Professional pre-treatment solution enables real-time monitoring with minimal maintenance and reduced labor costs.
  • Flexible Data Management: Multiple interface options for data transmission to centralized control systems.
Technical Specifications
Parameter Specification
Measured Components CO, CO₂, CH₄, C₃H₈, O₂, H₂S
Measurement Principle NDIR, ECD
Measurement Range CO/CO₂/CH₄/C₃H₈: (0-100)%
O₂: (0-25)%
H₂S: (0-9999) ppm
Linearity Error CO/CO₂/CH₄/C₃H₈: ±1%F.S.
O₂/H₂S: ±2%F.S.
Resolution 0.01% (1ppm for low-range)
Repeatability ≤ 2%
Response Time T90 ≤ 15s (NDIR)
Optimal Flow Rate (0.7-1.2) L/min
Inlet Pressure (2-50) kPa
Gas Requirements Dust-free, water-free, oil-free
Communication RS-485/RS-232; 4-20mA; Ethernet
Power Supply AC220V, 50Hz
Display LCD Display
Explosion-Proof Certification Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db
Functional Configuration Built-in zero-adjustment air pump, automatic air zero-adjustment, self-diagnosis function