Component Range:
O₂: 0 - 25%; COe: 0 - 10000ppm
Response Time:
O₂: T90 ≤ 10s; COe: T90 ≤ 20s
Measurement Accuracy:
O₂: ±1.0%F.S. Or 0.2%; COe: ±5%F.S. Or 25ppm
Resolution:
O₂: 0.01%COe: 1ppm
Communication Method:
RS - 485/MODBUS
Output:
2 - Way 4 - 20mA, 3 - Way Adjustable Alarm
Highlight:

Zirconia Gas Analyzer KGD - MQ - 511

,

In situ Zirconia Gas Analyzer

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
In-Situ Zirconia Gas Analyzer KGD-MQ-511
Product Overview

The In-Situ Zirconia Gas Analyzer KGD-MQ-511 is a high-temperature analyzer designed for simultaneous monitoring of oxygen and combustible gas (COe) content. Engineered for optimal combustion efficiency control, this analyzer operates reliably in harsh industrial environments with high temperatures and dust levels.

In - Situ Zirconia Gas Analyzer KGD - MQ - 511 0
Key Features
  • Simultaneous high-precision measurement of oxygen and combustible gas COe
  • Extended temperature range capability (up to 1500°C)
  • Temperature-stabilized sensor for consistent performance
  • Dust-resistant probe design with integrated filter and baffle system
  • Flange-mounted installation for direct process measurement
Technical Specifications
Parameter Specification
Component Range O₂: 0-25%; COe: 0-10000ppm
Response Time O₂: T90 ≤ 10s; COe: T90 ≤ 20s
Measurement Accuracy O₂: ±1.0%F.S. or 0.2%; COe: ±5%F.S. or 25ppm
Resolution O₂: 0.01%; COe: 1ppm
Communication RS-485/MODBUS
Output 2-way 4-20mA, 3-way adjustable alarm
Operating Temperature Control Unit: -40°C to 65°C; Sensor Unit: -40°C to 120°C
Protection Rating IP66
Probe Material S316L, Alloy 600, Alumina (custom lengths available)
Installation Flange DN50 (customizable)