Place of Origin:
CHINA
Brand Name:
KACISE
Certification:
CE
Model Number:
KGD-MQ-538
The KGD - MQ - 538 Trace Oxygen Analyzer utilizes limiting current-type zirconia sensor technology for precise ppm-level oxygen concentration measurement in industrial processes. With high accuracy, rapid response, and exceptional stability, this analyzer is ideal for semiconductor manufacturing, air separation, and inert gas welding applications. Its compact modular design ensures easy installation in complex environments while providing an intuitive user interface.
Measurement Principle | Limiting current-type zirconia method |
---|---|
Measuring Range | 0-100ppm; 0-1000ppm (automatic switching) |
Measurement Accuracy | ≤ ±2%F.S. |
Resolution | 0.1ppm |
Response Time | T90≤10s |
Operating Temperature | 0-50°C |
Relative Humidity | 0-95%RH |
Output Signals | 4-20mA, 0-5V DC, 0-10V DC |
Alarm Output | 2-way concentration alarm, 1-way fault alarm |
Communication | RS-232, RS-485 interfaces |
Power Supply | 12V DC/20V AC, 50Hz |
Dimensions | Meter: 178×107×95mm; Sensor: 38.1×71.5mm |