Place of Origin:
CHINA
Brand Name:
KACISE
Certification:
CE
Model Number:
KGD-WQ-510
The KGD-WQ-510 Motor Vehicle Brake Emission Testing System is a comprehensive solution designed for standardized testing of motor vehicle brake particle emissions. The system consists of an air duct control system, particle sampling system, particle number analysis system, inertial brake dynamometer, and main control system.
Primary test capabilities include PM2.5, PM10, SPN, and TPN measurements, meeting Euro 7 emission standard certification requirements and R&D testing needs.
Flow Control Range | 100 - 2000 m³/h |
Flow Control Stability | ≤ ±5% of set value |
Flow Measurement Accuracy | ≤ ±1.5% of reading |
Cooling Air Temperature | 23°C ± 2°C |
Cooling Air Humidity | 50% ± 5%RH |
Cooling Air Filtration | Activated carbon filter and H13-grade particle filter |
Maximum Particle Size Limit | 2.5μm and 10μm |
Filter Paper Sampling Temperature | ≥ 15°C (no condensation) |
Filter Paper Diameter | 47mm |
Sampling Flow Rate | 16.7 L/min |
Sampling Flow Control Accuracy | ≤ ±2% of set value |
Measurement Principle | Condensation Particle Counting (CPC) |
Measurement Items | TPM10; SPN10 |
Particle Size Range | 10 nm (65% ± 15% efficiency) to 2.5μm |
CPC Measurement Range | 0 - 100000 #/cm³ |
CPC Measurement Precision | ≤ ±10% |
Dilution Ratios | Primary: 10; Secondary: 10-30 |
VPR Removal Efficiency | >99.9% |
Response Time | T90 < 5s |
Send your inquiry directly to us