Measured Components:
CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ/Calorific Value
Measurement Principle:
CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD
Accuracy:
CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1%F.S.; H₂/O₂: ±2%F.S.
Explosion - Proof Grade:
Ex D ⅡC T4 Gb
Highlight:

On - Line Gas Analysis System

,

Gas Analysis System KGD - MQ - 505

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
On-Line Gas Analysis System KGD-MQ-505
Product Overview

The KGD-MQ-505 online gas analysis system is specifically engineered for high-dust sample gas environments. This comprehensive system integrates four key components: sampling probe, pretreatment unit, control unit, and gas analysis unit. Utilizing proprietary non-dispersive infrared (NDIR) technology, it provides continuous, simultaneous measurement of multiple gas components and calorific values in real-time.

On - Line Gas Analysis System KGD - MQ - 505 0
Key Specifications
Measured Components CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ/Calorific Value
Measurement Principle CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD
Accuracy CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1%F.S.; H₂/O₂: ±2%F.S.
Explosion-proof Grade Ex d ⅡC T4 Gb
System Features
  • Advanced Pretreatment Unit: Stainless steel, electrically heated temperature-controlled dry sampling probe with automatic purging technology prevents probe blockage. Features single-stage refrigerator for moisture removal and two-stage filtration for reliable long-term operation.
  • Intelligent Control Unit: PLC-controlled automation handles sampling, back-flushing, and drainage operations with minimal manual intervention.
  • Comprehensive Gas Analysis: Simultaneously measures volume concentrations of multiple gas components (CO, CO₂, CH₄, H₂, O₂, C₂H₂, C₂H₄, CₙHₘ) and automatically calculates/display calorific values.
  • Enhanced Safety: Ex d IIC T4 Gb explosion-proof rating ensures operation in hazardous environments.
  • Cost-Efficient Operation: Real-time system monitoring reduces maintenance requirements and operational costs.
  • Smart Data Integration: Multiple interface options (RS-232/RS-485, 4-20mA, Ethernet) for seamless data transmission to centralized control systems.
Technical Parameters
Measurement Range CO/CO₂/CH₄/H₂: (0-100)%
O₂: (0-25)%
C₂H₂/C₂H₄/CₙHₘ: (0-10)% (Optional)
Electrical Parameters Standard industrial power requirements
Display LCD Display
Communication RS-232/RS-485, (4-20)mA, Ethernet
Functional Configuration Self-diagnosis function for sensor status check
Internal zero-adjustment air source for automatic calibration
Industrial Applications: Ideal for online gas monitoring in blast furnace gas, converter gas, coke oven gas, and CDQ circulating gas electric furnace processes. Enhances gas utilization efficiency, promotes energy conservation, and ensures production safety.