Place of Origin:
CHINA
Brand Name:
KACISE
Certification:
CE
Model Number:
KUS3000-M18
Document:
Attribute | Value |
---|---|
Product | Ultrasonic Distance Sensor |
Detection Range | 50mm~1000mm |
Transducer Frequency | 40KHZ |
Operating Voltage | 24VDC |
Limit Working Voltage | 3.6VDC~30VDC |
IP grade | IP67 |
Output | RS232/RS485 |
Sensing range | 100...1000 mm |
Unusable area | 0...100 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx.220 kHz |
Response delay | approx. 50 ms |
LED blue | power-on |
LED yellow | indication of the switching state flashing: program function object detected |
LED red | permanently red: Error Red,flashing:program function,object not detected |
Operating voltage UB | 15...30 V DC , ripple 10 %SS |
No-load supply current I0 | ≤ 45 mA |
Input type | 1 TEACH-IN input |
Operating range | A1: -UB ... +1 V, A2: +6 V ...+UB |
Input impedance | > 4.7 kΩ |
TEACH-IN program pulse | ≥ 1 s |
Output type | 1 switch output E4, NPN NO/NC,programmable |
Rated operating current Ie | 200 mA , short-circuit/overload protected |
Default setting | Switching point A1:70mm Switching point A2: 800mm |
Voltage drop | ≤ 2.5 V |
Repeat accuracy | ≤1 % |
Switching frequency f | ≤ 13 Hz |
Range hysteresis H | 2 % of the set operating distance |
Temperature influence | ±1.5% of full-scale value |
Ambient temperature | -25...70℃(248...343K) |
Storage temperature | -40...85℃(233...358K) |
Connection | V1 connector(M12×1),4-pin |
Protection degree | IP67 |
Material Housing | brass, nickel-plated |
Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - UB, A2 with +UB. Eight different output functions can be set.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power on. If want to change the switching point, the user can only setting the request distance after power restart.
A1=blind range, A2=nominal distance
Displays in dependence on operating mode | Red LED | Yellow LED |
TEACH-IN switching point Object detected No object detected Object uncertain(TEACH-IN invalid) | off flashes On | flashes off off |
Normal operation | off | Switching state |
Fault | on | Previous state |
If the sensor is installed at the environment temperature fall below 0℃, it should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
Send your inquiry directly to us