Wirless Ultrasonic Btu Building Water Meter Lora / GPRS Explosion Proof

Wirless Ultrasonic Btu Building Water Meter Lora / GPRS Explosion Proof

ultrasonic btu meter

m bus water meter

Place of Origin:

China

Brand Name:

Kacise

Certification:

CE / ISO / Explosion-proof

Model Number:

KUHM2100

Contact Us
Request A Quote
Product Details
DN(mm):
DN15~DN300
Pressure:
1.6MPa
Connection:
DN15~DN40 Threaded / DN50~DN300 Flange Connection
Communication:
RS-485 / MBUS / Lora433MHZor 868MHZ / GPRS
Accuracy:
Class 2
Protection:
IP67 / IP68
Installation:
Default Is Inflow, For Return Flow Need To Indicate When Ordering
Power Supply:
High Power Lithium Battery
Temp. Sensor:
1.5m Standard A Pair Of PT1000 Temperature Senso
Highlight:

ultrasonic btu meter

,

m bus water meter

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiable
Packaging Details
Carton / Wooden Box
Delivery Time
5~8 working days
Payment Terms
L/C, D/A, T/T, Western Union, MoneyGram
Supply Ability
1000pcs
Product Description

Mbus Output Ultrasonic Btu Meter Ultrasonic Heat Meter For Residence / Apartments / Buildings

 

 

 

Description

 

KACISE KUHM2100 series heat meters adopt most advanced non-magnetic technology and it features elegant appearance, accurate measurement, convenient management, steady operation, strong anti-erosion, and long using life, which is secure and economic.
It is widely used in the heat system with concentrated heat supplying management, separate household data collecting management.
Varies of communication modes are optional according to the users’ need..

 

Features

 

☆ Measure Heat.
☆ Show supply/return water temperature and differential temperature.
☆ Display pile flow measure and instantaneous flow measure.
☆ Running time display.
☆ Cold measure and display (for heat/cold Ultrasonic Heat Meter )

 

Specifications

Nominal Diameter DN15 DN20 DN25 DN32 DN40
Dimension (Length mm) 110 130 160 180 200
Max flow (m3/h) 3 5 7 12 20
Norm flow(m3/h) 1.5 2.5 3.5 6 10
Min flow(m3/h) 0.03 0.05 0.07 0.12 0.2
Max flow reading 999999.99(m3)
Max heat reading 99999999(KW·h)
Power supply 3.6VDC
Battery life >6 years ( Lithium battery)
Accuracy class Class 2
Communication mode Infrared interface , M-BUS/RS485 / lorawan / GPRS
Press loss ≤ 0.025 Mpa ( under normal flow)
IP class IP 68
Temperature range (4--95) °C
Temperature difference range (3--70) k
Starting temperature difference 0.01k
Temperature sensor Pt 1000
Ambient temperature +5°C -- +55°C
Ambient level Level A
Installation Horizontal/ vertical installation
Monitor 8 digits
Length of temperature sensor 1.5m
Working current 45uA
Data storage Store historical data up to last 24 months

 

Installation and Attentions

The heat meter both can be installed in Inflow pipe or Return flow pipe (factory default installed in the inflow pipe, if need to install on the return pipe, must be clearly indication before the factory during the production). When installation, should pay attention to the flow direction of medium is as the same as the arrow on the heat meter pipe body.

Special note: no matter the heat meter installed on inflow pipe or return flow pipe, the temperature sensor should be properly connected ( red label for inflow pipe, blue label for return pipe)

Wirless Ultrasonic Btu Building Water Meter Lora / GPRS Explosion Proof 0

Instrument Common Problem

 

The meter cannot work normally

Heating system is working or not;

Globe valve is opened entirely or not;

the pipe is blocked or not;

the lead seal is complete or not;

Battery is good or not;

heat meter isn’t counting

①,heat meter reversed installation

②,transducer cables are broken

③,the filter is be blocked on heat supply pipe of in the resident room

How to determine the filter whether block?

Inflow temp. is normal, return flow temp. is too low, the temp. difference of inflow and return flow is more than 10°, flow rate is too low(m3/h), or now flow rate, usually the filter is blockage, or user does not use.

Solution:Close the valve (inflow and return flow valve), remove the filter, to observe whether filter is black, clean filter and inside of it, then install the filter, open pipe valves, wait 3 mins to check whether the flow rate and temp. is normal.

Heat meter data abnormal or jumping

①,Installation position is not correct, down water level

②,Front and back straight pipes are too short, bend is too big, front pipe diameter is

changing bigger.

Heat meter has flow quantity, no heat, or heat is very big

①,Without heat is usually reversed installation of inflow and return flow temp. sensors

②,Heat is very big, because the temp. sensor measure temp. incorrectly, temp. difference is very big.

Heat meter abnormal temp., or the temp. is 0

①,the temp. sensor cable is broken

②,Temp. sensor stainless steel casing is broken.

 

Technical Specification

 

Diameter Min Flow Quantity of Flow Max Flow Length
qmin(m³/h) qp(m³/h) qmax(m³/h) mm
DN15 0.03 1.5 3 110
DN20 0.05 2.5 5 130
DN25 0.07 3.5 7 160
DN32 0.12 6 12 180
DN40 0.2 10 20 200
Measurement Accuracy CJ128-2007<Heat Meter>Class 2
Connection DN15~DN40 Threaded connection/DN50~DN300 Flange connection
Pressure Loss ≤0.02MPa
Maximum Working Pressure(MWP) 1.6MPa
Flow Measuring Range 1:100
Temperature Sensor 1.5m standard a pair of PT1000 Temperature Sensor (cable length could be changed)
Data Storage Continuous store of 18 months record
Power-off Protection After power-off, meter could save all the record of before flow rate and the corresponding time, after power back, it recovery measure function automatically, and ensure the time continuation
Remote Transmission MBUS/RS-485
Power Supply High Power Lithium battery
Protection Class IP67 (IP68 need to modified)
Environmental Class Class B
Temperature Range (5~95)℃
Temperature Difference (3~90)K
Installation Way Inflow or Return flow(Default is Inflow, for return flow need to indicate when ordering)
Installation Position Horizontal / Vertical
Permanence Service cycle≥6 years
Display 8-bit LCD display
Anti-magnetic Disturbance When the intensity of magnetic field interference is not more than 100 ka/m, should not affect water meter measurement and remote transmission characteristics
 

 