Product Details:
Place of Origin: CHINA
Brand Name: kacise
Certification: CE,FDA
Model Number: KBU601
Payment & Shipping Terms:
Minimum Order Quantity: 0-100
Price: $100-$2000
Packaging Details: Common package or custom package
Delivery Time: 10-15 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100
Contact Now
Detailed Product Description
Measuring Range: 0-14PH;-2000mv-2000mv Precision: 2% Calibration Accuracy
Supply Voltage: AC220V Or DC24V (choose One Of The Two) Power Consumption: <1W
Display: LCD Chinese Display/TFT Color LCD (customized Version) Sensor:Protection Level: Ip68
High Light:

14PH Water Quality Monitoring Equipment

,

AC220V Water Quality Monitoring Equipment

,

ORP water turbidity sensor

KPH500 Ph Sensor Ph0-14 Ph Test Sensor Module Water Quality Probe Ph water quality monitoring equipment

Production Introduction

The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is widely used in agriculture, environmental protection and industry.

 

 

 

The sensor uses a composite electrode, which can eliminate the influence of the inconstant "K" value,

A long-term, stable and accurate measurement of PH is realized. The internal structure of the sensor is shown on the right.

 

 

AC220V KPH500 Ph0-14 Water Quality Monitoring Equipment 0

 

 

 

Features

 

1. LCD display, Chinese menu operation, stable performance and strong reliability

2. High-performance operational amplifier, ORP positive and negative poles are symmetrical, small drift, high accuracy

3. Data is not lost after power off

4. Dual 4-20mA transmission output, relay high and low alarm control output, RS485 communication

Output

5. Simultaneous display of PH value, temperature value, output current value, high alarm value, low alarm value

 

 

 

 

PH/ORP size structure chart

 

Host size

 

 

 

AC220V KPH500 Ph0-14 Water Quality Monitoring Equipment 1

 

 

Sensor size

 

AC220V KPH500 Ph0-14 Water Quality Monitoring Equipment 2

 

AC220V KPH500 Ph0-14 Water Quality Monitoring Equipment 3

 

 

 

PH/ORP technical parameters

 

 

 

Class Performance PH parameter OPR parameter
Host Measuring range 0-14PH -2000mv-2000mv
Resolution 0.01PH 1mv
Precision 2% Calibration accuracy
Operating Temperature Transmitter 0-65℃
Material PVC
Protection Level I65/IP67(customized version)
Signal Output

485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

Communication (function option)

Supply Voltage AC220V or DC24V (choose one of the two)
Power Consumption <1W
Display LCD Chinese display/TFT color LCD (customized version)
Installation Method Wall mount
Sensor Temperature Compensation Automatic temperature compensation
Protection Level ip68
Temperature 0-60℃
Sensor Material PVC
Cable Length Dedicated PH cable, standard 5 meters (extendable)
Operating Temperature 0-60℃
Storage Temperature -10-60℃
Installation Method Bracket drop-in installation

 

 

 

Ordering Information Selection Table
KPH500 PH/ORP analyzer
Power supply DC24V
AC220V
Cable length 5m
10m
15m
20m
Temperature compensation Sensor without temperature compensation
Sensor with temperature compensation
Signal output Only 4-20mA
Only 485
Also with 4-20mA , 485 signal output
Special custom signal
KPH500-P-DC24V-5m-Sensor without temperature compensation-Only 485 PH host, with DC24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.
KPH500-R-AC220V-10m-Sensor with temperature compensation-Only 485

Optional ORP host, with 220V adapter, line between host and sensor

The cable length is 10 meters, the sensor with temperature compensation, and is equipped with only 485 communication signal output.

 

 

Q&A

 

 

How is ORP calculated?

ORP is determined by measuring the potential of a chemically-inert (platinum) electrode which is immersed in the solution. The sensing electrode potential is read relative to the reference electrode of the pH probe and the value is presented in millivolts (mV).2015年11月19日

 

How do I lower my ORP?

Factors that can lower ORP in pools.

In pool water chemistry, once added to the water all chlorine oxidizers, including salt, produce hypochlorous acid (HOCl), hypochlorite ions (OClᐨ) and a by product specific to the type of chlorine being used.2019年2月15日

 

 

Does pH affect oxidation?

The dissolved oxygen concentration increases and because the reaction in the broth is an oxidation process, the redox is also increasing. Oxidation also increases with pH decreasing but why? When I am supplying oxygen for a long time, redox decreases as well as the pH also behaves the same way.

 

 

How can I lower my water ORP?

Lowering the pH to 6.0 raises the ORP, as more hypochlorous acid (HOCl) becomes available. Raising the pH to 8.0 lowers the ORP value, as more hypochlorite ions (OCl–) are present. Maintaining constant pH but adding more chlorine raises the ORP to a plateau of 900 to 950 mV, generally around 25 ppm HOCl.

 

 

What is pH?

pH is a measure of how acidic/basic water is. The range goes from 0 to 14, with 7 being neutral. pHs of less than 7 indicate acidity, whereas a pH of greater than 7 indicates a base. The pH of water is a very important measurement concerning water quality.

 

Contact us

Website: www.kacise.com

Phone: +86-17719566736

Email: sales@kacise.com

Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.