Send Message
Home ProductsWater Quality Sensor

RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601

RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601

  • RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601
  • RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601
RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601
Product Details:
Place of Origin: CHINA
Brand Name: kacise
Certification: CE
Model Number: KFDO601
Payment & Shipping Terms:
Minimum Order Quantity: 0-100
Price: $0-$2000
Packaging Details: Common package or custom package
Delivery Time: 3-10days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100
Contact Now
Detailed Product Description
Measuring Principle: Fluorescence Method Range Ability: 0~20mg/L (0 ≤ 200% Saturation)
Resolution Ratio: 0.01mg/L,0.1℃ Precision: ±2%F.S.,±0.5℃
Temperature Compensation: Automatic Temperature Compensation(Pt1000) Output Mode: RS-485 Bus, Modbus-RTU Protocol
High Light:

Dissolved Oxygen Sensor RS485 Interface

,

Dissolved Oxygen Sensor Anti Interference

KFDO601 Online Fluorescence Dissolved Oxygen No Electrolyte Is Required And Will Not Be Polarized No Oxygen Consumption

 

1.Dissolved oxygen measurement applications

  • Food and Beverages
  • The pharmaceutical
  • Energy and electricity
  • education
  • The government
  • water
  • Waste water management

2.the Difference of Polarographic probe and optical probe

  Polarographic probe optical probe
maintence Replace the electrolyte approximately every 2 months and polish the cathode as needed to clean the probe Clean probe, cover and optical window as needed
storage Stored in a wet calibration sleeve;For long-term storage, remove the film cover and store in a dry place Store in a wet calibration sleeve
film Replace approximately every 2 months as needed no
solution Replace approximately every 2 months as needed no
Need to preheat (30-60 minutes) if only connected to the meter  
stir need unnecessary
disturb Ozone, sulfides, sulfur dioxide, nitrous oxide and carbon monoxide  

3.Feature

  • No electrolyte is required and will not be polarized.
  • No oxygen consumption, not affected by flow rate.
  • Built-in temperature sensor, automatic temperature compensation.
  • Free from interference by chemicals such as sulfides
  • Small drift, rapid reaction, more accurate measurement.
  • Long service cycle, lower cost of use.
  • Simple replacement of fluorescent cap.
  • Rs-485 interface, Modbus/RTU protocol.
  • Low power consumption,anti-interference.

4.Technical Specifications

Model KFDO601
Measuring principle Fluorescence method
Range ability 0~20mg/L (0 ≤ 200% saturation)
Resolution ratio 0.01mg/L,0.1℃
Precision ±2%F.S.,±0.5℃
Temperature compensation Automatic temperature compensation(Pt1000)
Output mode RS-485 bus, Modbus-RTU protocol
Working conditions 0~45℃,<0.2MPa
Storage temperature -5~65℃
Installation mode Immersion mounting
Cable length 5 meters, other lengths customizable
Power dissipation <0.3W@12V
Source 12~24VDC ±10%
levels of protection IP68
Calibration Two-point calibration
Fluorescent cap life Guaranteed use for one year (under normal use)
Sensor shell material POM and 316L stainless steel
 

5.Dimensional Drawing

RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601 0

Note:The sensor connector is m16-5 core waterproof connector male.

6.Installation

 

RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601 1

 

 

The sensor shall be installed fixedly below the liquid level. The installation and use shall avoid collision or scraping against the surface of the fluorescent film head. The fluorescent film head part shall avoid being attached by the bottom sediment.Remove the rubber cover when use.

 

Contact Us

Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601 2

 

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.