Place of Origin: | CHINA |
Brand Name: | kacise |
Certification: | CE |
Model Number: | KAN310 |
Minimum Order Quantity: | 0-100 |
---|---|
Price: | $0-$500 |
Packaging Details: | Common package or custom package |
Delivery Time: | 3-10days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 100 |
Range: | 0 ~ 10.00 Mg/L (0 ~ 100.00 Mg/L) | Resolution: | 0.01 Mg/L |
---|---|---|---|
Precision: | ± 10% Or ± 1mg/L | Operating Temperature: | 0 ~ 40 °C |
Working Pressure: | < 0.1 Mpa | The Ph Range Of The Medium: | 4 ~ 10ph |
High Light: | PLC Connect Nitrogen Sensor,Submerged Installation Nitrogen Sensor |
KAN310 integrated on-line ammonia-nitrogen sensor is made of ammonium ion selective electrode based on PVC membrane, which is used to measure the content of ammonium ion in water with temperature compensation.
Model Number | KAN310 |
Range | 0 ~ 10.00 mg/L (0 ~ 100.00 mg/L) |
Resolution | 0.01 MGL |
Precision | ± 10% or ± 1MG/L |
Operating Temperature | 0 ~ 40 °C |
Working Pressure | < 0.1 mpa |
The Ph Range Of The Medium | 4 ~ 10ph |
Temperature Compensation | Automatic temperature compensation (PT1000) |
Power Supply | 12 ~ 24 VDC ± 10% |
Signal Output | RS-485 bus, Modbus/RTU protocol |
Contact Material | PVC and POM |
Installation Mode | Immersion mounting |
Cable Length | 5 meters, other length can be customized |
Calibration Mode | Two-point calibration |
Power Consumption | < 0.05 W |
Protection Level | IP68 |
To sum up, ammonia nitrogen pollution has become the main stress factor restricting the aquaculture environment. The ammonia nitrogen pollution produced in aquaculture has been listed as one of the pollutants for mandatory emission reduction in environmental protection and has been researched by environmental protection workers and technology. The extensive attention and research of the authors, the determination of ammonia nitrogen in the aquaculture water body, helps to evaluate the pollution and "self-purification" of the water body. Several existing detection methods have certain defects. For example, the Nadler reagent spectrophotometry has high requirements for the preparation of chromogenic reagents. The amount of HgCI2 added determines the number of chromogenic groups obtained, which in turn affects the sensitivity of the method. However, the method does not give the exact dosage, and it needs to be judged based on the phenomenon in the reagent preparation process, which is highly empirical and therefore difficult to grasp. Due to the narrow oxidation range of gas-phase molecular absorption spectrometry, the use of a direct measurement standard curve will cause large errors. The aquaculture water contains a large amount of nitrate nitrogen, which will cause strong interference in the determination of ammonia nitrogen and affect the measurement results. The hypobromite oxidation method has a large error when it is used to determine the aquaculture water containing more organic matter, and the blank value of the aquaculture water sample is high, which will cause serious interference. All these problems require us to further study and improve, to improve the detection method of ammonia nitrogen in aquaculture water samples, to accurately grasp the change of ammonia nitrogen in aquaculture water samples, to reduce the harm of ammonia nitrogen to aquatic organisms and to protect human health.