logo
Home > Products > Water Quality Sensor >
IP68 Water Chlorine Sensor with 0.001mg/L Resolution Using Constant Voltage Method for Accurate Residual Chlorine Monitoring

IP68 Water Chlorine Sensor with 0.001mg/L Resolution Using Constant Voltage Method for Accurate Residual Chlorine Monitoring

water chlorine sensor for pools

water quality sensor with warranty

chlorine sensor for water testing

Contact Us
Request A Quote
Product Details
Resolution:
0.001mg/L
Working Temperature:
0 ~ 50℃
Power Supply:
12~24VDC±10%
Product Name:
Residual Chlorine Sensor
Protection:
IP68
Principle:
The Constant Voltage Method
Port:
Xi'an Or Other
Range:
0~2.000mg/L(HClO)
Accurate:
±5% Or ±0.05mg/L
Highlight:

water chlorine sensor for pools

,

water quality sensor with warranty

,

chlorine sensor for water testing

Payment & Shipping Terms
Price
$500.00 - $700.00/pieces
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Supply Ability
500 Piece/Pieces per Month
Product Description
Water Chlorine Sensor
1. Applications

Kacise on-line residual chlorine sensor is used to monitor the residual chlorine content continuously in drinking water treatment plant, canning plant, drinking water distribution network, swimming pool, cooling circulating water, water quality treatment project.

2. Technical Specifications
Module No. KWS-3000
Principle the constant voltage method
Range 0~2.000mg/L(HClO)
Accurate ±5% or ±0.05mg/L
Resolution 0.001mg/L
Calibration Function Two point Calibration (Zero and Slope )
Temperature Compensation Temperature compensation automatically (Digit temperature sensor)
Working temperature 0 ~ 50℃
Output Support RS-485, MODBUS protocol
Power Supply 12~24VDC±10%
Velocity 30-60 L/h
Installation Circulation pool installation
size 30×233mm(Φ×L)
Protection IP68
Material Polyacetal resin, PTFE, Gold, Silver
Polyformaldehyde resin, teflon, gold, silver, electro conductive rubber
3 Outline

IP68 Water Chlorine Sensor with 0.001mg/L Resolution Using Constant Voltage Method for Accurate Residual Chlorine Monitoring 0

4 Electric Connect

The electrode should be installed closely with the circulation pool. The electrode measurement part should be placed in the area near the circulation pool inlet. It is not allowed to face the outlet. Ensure the smooth flow. We suggest to control the flow rate within 30-60l /h to ensure the test accuracy.

Red: Power supply (12~24V)

Black: Ground(GND)

Blue: 485A

White: 485B

Exposed wire: shielded wire

Please make sure that you connect the wire correctly.

Cable specifications: the cable has a certain corrosion resistance, considering that it has been immersed in water (including seawater) or exposed to air for a long time. The diameter is Φ6 mm. Please make the waterproof processing on cable joint.

5 Maintenance

1) Sensor detection and maintenance

The new electrode and the electrode placed for a long time should be activated before use. The sensor shall be left in the tap water for 24 hours.If the returned value is not correct, please make the following operation.

  • Calibration of zero point and slope of electrode
  • Returned to the factory for inspection.

2) Calibration of sensors

a) zero point calibration: the sensor probe is placed in chlorine-free water for zero point calibration after the numerical stability.

b) slope calibration: the sensor probe is placed in the flow pool with residual chlorine standard liquid, and the slope calibration is performed after the value is stable. Suggest to use 1-2mg/L HCIO standard solution. About the preparation and determination of the standard liquid, we can refer to the determination of residual chlorine standard.

Note: the sensor has been calibrated before delivery. Since the preparation of its standard liquid has high requirements on personnel, non-professionals may not be qualified for this job. Only if the value is determined to be inaccurate, it is recommended that the user do not calibrate the sensor.