Place of Origin:
china
Brand Name:
KACISE
Certification:
CE
Model Number:
KFQ100
Float Level Switches Made of SUS304/SUS316/PP/PE/PTFE Materials
Our float level switches are crafted from high - quality SUS304, SUS316, PP, PE, and PTFE materials, each offering unique advantages.
SUS304 and SUS316 models feature excellent corrosion resistance, suitable for various industrial liquids. They can withstand high temperatures and pressures, ensuring reliable performance. PP and PE - made switches are lightweight and cost - effective, with good chemical resistance, ideal for common corrosive media. The PTFE - based ones are top - notch in terms of chemical stability, capable of handling extreme corrosive substances.
These float level switches are easy to install and maintain, providing accurate and stable liquid - level monitoring for applications in chemical, food, pharmaceutical, and water treatment industries.
Contact Capacity: 10W, 30W, 50W
Switch Current: 0.5A
Switch Voltage: 220VAC/24VDC
Insulation Resistance: > 100MΩ
Working Life: 1 million times
Working Pressure: 1.0~3.0 MPa
Working Temperature: SUS: -20~200℃ PP: -10~80℃
Medium Specific Gravity: >0.55
Product Material: SUS304/SUS316/PP/PE/PTFE
Connecting Rod Float | Sample Diagram of Connecting Rod Float |
![]() |
![]() |
The installation position should be kept away from the water inlet, otherwise the switch may malfunction due to the water inlet.
If the switch is installed on the concrete pool wall, an L-shaped angle steel bracket can be added.
If the switch is installed in the stirring area, a wave-proof tube or wave-proof baffle can be installed.
Select a flange connection pipe with an inner diameter larger than the diameter of the floating ball.
The specific gravity of the liquid being measured must be greater than that of the floating ball.
Plastic materials are suitable for acidic and alkaline liquids, while metal materials are suitable for high-temperature liquids such as fuel oil.
The action point of the floating ball has been adjusted at the factory according to the customer's ordering requirements. Please do not adjust the position of the floating ball at will.
The connected load capacity must not exceed the output point capacity.
Send your inquiry directly to us