1.Instruction
Meet the KACISE Outdoor High - Performance KLSA Laser Distance Sensor. Laser distance sensor is a precision instrument that uses laser technology to achieve non-contact distance measurement. It determines the distance, position or displacement of the target object by emitting laser and analyzing the reflected signal. Its core advantages are high precision, long distance, fast response and anti-interference ability. It is widely used in industrial automation, intelligent equipment, surveying and remote sensing, consumer electronics and other fields.
2.Features
3.Technical Specifications
Performance parameters | |||||
Measurement range | Maximum measuring distance: 22m | ||||
Under strong light @100KLux environment: 12m | |||||
Under black target with 10% reflectivity: 20m | |||||
Measurement frequency | 100HZ (frequency adjustable) | ||||
Repeat accuracy | ±8.0mm @50~2000mm | ||||
±20.0mm @2000~6000mm | |||||
±30.0mm @6000~20000mm | |||||
Absolute accuracy | ±20.0mm@200~2000mm; 20~200mm near blind area, large error | ||||
±30.0mm @2000~6000mm | |||||
<1% @6000~20000mm | |||||
Multi-target detection | Double peak | ||||
Temperature compensation | Yes | ||||
Reflectivity correction | Yes, the deviation of different color targets is less than 5mm | ||||
Blind area | 0.03m | ||||
Light source | |||||
Working laser | 905nm,Class 1 | ||||
Field of view FOV | <2° | ||||
Spot size |
Φ3.5cm@1m: Φ11.5cm@5m Φ23cm@10m; Φ50cm@20m |
||||
Indicator laser | 650-660nm,Class 2, (IEC 60825-1:2014, EN 60825-1:2014) | ||||
Working environment | |||||
Working temperature | -20~50℃ | ||||
Storage temperature | -40~85℃ | ||||
Enclosure protection level | IP65 | ||||
Electrical Parameters | |||||
Working voltage | DC+9~35V | ||||
Working current | 107mA@12V indicates laser working | ||||
103mA@12V indicates laser off | |||||
Reverse protection | Yes | ||||
Isolation | Yes | ||||
Laser life | More than 50000h | ||||
Output interface | |||||
Output interface | Two-way PNP | Two-way NPN | RS485-Modbus |
UART
|
Relay |
Normally open/closed | Normally open/closed | 4~20mA | |||
Switch output maximum current load | 100mA | ||||
Analog output maximum load | 250Ω | ||||
Display button | |||||
Nixie tube digits | 4-bit | ||||
Button function | Switch value adjustment; laser switch indication; analog range adjustment | ||||
Mechanical parameters | |||||
Weight | 73g+3g (glue filling error) | ||||
Casing | ABS | ||||
Dimensions | 45*45*49.5mm | ||||
Accessories | |||||
Bolts | M4*55mm 2 | ||||
Bracket | Optional | ||||
Electrical connection | 1*M8, 1 meter long cable |
4.Dimension
5.Installation
Installation conditions
► Install the device so that the object to be measured is within the measuring range of 0.03...22 m.
► The sensor has a fixed accuracy range of 22 m. Do not measure objects within a range > 22 m.
► The customer should also avoid reflective objects in the direct optical path of the sensor within a range > 22 m. Otherwise, the measured values may be inaccurate.
Install accessories
6.Cable Definition
NO. | Line Color | KLSA-P/N | KLSA-DA | KLSA-T |
1 | Brown | VCC, DC9-35V | VCC, DC9~35V | VCC, DC3.3V |
2 | Black | GND | GND, analog ground | Power ground |
3 | Blue | OUT1 | RS485 A | RX |
4 | White | OUT2 | RS485 B | TX |
5 | Gray | None | Analog output |
7.Order Model Table
Range | Interface | Model |
1m | PNP | KLSA-01P |
2m | PNP | KLSA-02P |
3m | PNP | KLSA-03P |
4m | PNP | KLSA-04P |
5m | PNP | KLSA-05P |
NPN | KLSA-05N | |
RS485/4-20mA | KLSA-05DA | |
Relay | KLSA-05R | |
10m | PNP | KLSA-10P |
NPN | KLSA-10N | |
RS485/4-20mA | KLSA-10DA | |
Relay | KLSA-10R | |
20m | PNP | KLSA-20P |
NPN | KLSA-20N | |
RS485/4-20mA | KLSA-20DA | |
Relay | KLSA-20R | |
UART TTL | KLSA-20T |