Measuring Principle:
Scattered Light Method
Measuring Range:
0 To 2000 Mg / L
Resolution:
0.1 Mg/L, 0.1 °C
Precision:
± 5%
Calibration Method:
Two-point Calibration
Temperature Compensation:
Automatic Temperature Compensation (Pt1000 )
Highlight:

Scattered Light Method TSS Sensor

,

2000 mg/L Online TSS Sensor

,

KWS-950S Online TSS Sensor

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
KWS-950S Online TSS Sensor
Product Overview

The KWS-950 integrated online TSS sensor utilizes scattered light suspension measurement technology. When light passes through a water sample, suspended particles scatter the light. By measuring the intensity of scattered light perpendicular to the incident beam and comparing it with internal calibration values, the sensor calculates and linearizes the output to provide accurate TSS measurements.

Key Features
  • Operating range: 0 to 50°C with IP68 protection for water depths up to 20 meters
  • Scattered light measurement principle with integrated temperature sensor
  • RS-485 communication supporting Modbus/RTU protocol
  • Fiber-optic design for superior resistance to external light interference
  • Infrared LED light source ensuring high measurement stability
  • Convenient installation, stable performance, and easy maintenance
Technical Specifications
Model KWS-950S
Measuring Principle Scattered light method
Measuring Range 0 to 2000 mg/L
Resolution 0.1 mg/L, 0.1°C
Precision ±5%
Calibration Method Two-point calibration
Temperature Compensation Automatic temperature compensation (Pt1000)
Output Method RS-485 (Modbus/RTU)
Working Conditions 0 to 50°C, <0.2MPa
Storage Temperature -5 to 65°C
Installation Method Immersion mounting, 3/4" NPT thread
Cable Length 5 meters (custom lengths available)
Power Consumption <0.5W
Power Supply 12 to 24 VDC ±10%
Protection Level IP68
Casing Material Stainless steel
Self-Cleaning Function Selectable option