Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED Light Source

0-2000 NTU range Turbidity Detector

Surface scattering method Turbidity Analyzer

LED light source Water Quality Sensor

Brand Name:

Yokogawa

Model Number:

TB830D

Contact Us
Request A Quote
Product Details
Measuring Method:
Surface Scattering Method
Measuring Range (Turbidity Standard: Formazin):
0-2 To 0-2000 NTU
Temperature:
0 To 50°C
Flow Rate:
1.5 To 2 L/min
Pressure:
500 KPa Max
Highlight:

0-2000 NTU range Turbidity Detector

,

Surface scattering method Turbidity Analyzer

,

LED light source Water Quality Sensor

Payment & Shipping Terms
Minimum Order Quantity
1pcs
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
Surface Scattering Light Turbidity Detector TB830D
Digital Solution for Water Quality Analysis
Reduce Maintenance with Advanced Technology
Many of our customers face operational challenges - Yokogawa Turbidity Analyzers TB800 series provide reliable solutions.
Yokogawa's turbidity meters have been developed and improved to suit various applications in water treatment plant turbidity measurement. As a result, we have accumulated many achievements and gained the trust of our customers since our first product was launched in 1959.
The TB830D is part of the SENCOM4.0 platform family and can connect to FLXA402T. Thanks to a smart unit equipped detector, TB830D provides enhanced operational insight.
The TB830D is a turbidity analyzer equipped with LEDs as the light source, offering dirt-resistant design, reliable measurements, and reduced operational expenses through advanced diagnostic functions.
*Based on a Yokogawa survey in 2019
Advanced Measurement Technology
Less Susceptible to Contamination Due to Non-Contact Design
Compatible with Various Applications
  • Surface scattering measurement method minimizes contamination
  • LED light source for 3-year long life and reduced maintenance costs
  • High sensitivity and high accuracy with long-standing reliability
  • Good linearity and reproducibility
  • Measuring range from 0-2 NTU to 0-2000 NTU
  • Improved cleaning system reduces maintenance
  • Easy-to-clean cell structure (by GS)
Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED Light Source 0
Multi-sensor Input: Not only Turbidity Detector but also Chlorine Sensor Unit, pH sensor and conductivity sensor are connectable to one transmitter.
Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED Light Source 1
Applications
Turbidity Measurement for Tap Water, Sewage, River Water and General Process Water
Water Purification Treatment
  • Sedimentation
  • Flocculation
  • Settling Basins
  • Clean water reservoir
  • Distributing pump
  • Distribution tank & Piping
Wastewater Treatment
  • Discharge/Reuse
Surface Scattering Light Turbidity Detector TB830D with 0-2000 NTU Range and LED Light Source 2
Specifications
Measuring method Surface scattering method
Measuring Range
(Turbidity standard: Formazin)
0-2 to 0-2000 NTU
Sample Conditions Temperature: 0 to 50°C
Flow Rate: 1.5 to 2 L/min
Pressure: 500 kPa max
Power Supply 100 to 240 V DC, 50/60 Hz
Digital Communication Modbus TCP/IP, Modbus RTU
Installation Indoor (Outdoor use requires protection against rain. Direct sunlight must be avoided.)
Cleaning system Automatic wash
Performance
Linearity 0-1000 NTU: ±2% of reading or ±0.04 NTU whichever is greater
Over 1000 NTU: ±4% of reading
Repeatability ±1% of reading or ±0.02 NTU whichever is greater