Place of Origin:
Switzerland
Brand Name:
Endress+Hauser
Certification:
CE
Model Number:
Proline Promag P 300
High-temperature flowmeter for process applications with a compact, easily accessible transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
| Specification | Details |
|---|---|
| Maximum Measurement Error | Volume flow (standard): ±0.5% o.r. ± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2% o.r. ± 2 mm/s (0.08 in/s), Flat Spec |
| Measuring Range | 4 dm³/min to 9600 m³/h (1 gal/min to 44,000 gal/min) |
| Medium Temperature Range | Liner material PFA: -20 to +150°C (-4 to +302°F) Liner material PFA high-temperature: -20 to +180°C (-4 to +356°F) Liner material PTFE: -40 to +130°C (-40 to +266°F) |
| Maximum Process Pressure | PN 40, Class 300, 20K |
| Nominal Diameter Range | DN 15 to 600 (½ to 24") |
| Parameter | Specification |
|---|---|
| Wetted Materials | Liner: PFA; PTFE Electrodes: 1.4435 (F316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium |
| Measured Variables | Volume flow, conductivity, mass flow |
| Ambient Temperature Range | Flange material carbon steel: -10 to +60°C (+14 to +140°F) Flange material stainless steel: -40 to +60°C (-40 to +140°F) |
| Degree of Protection | Standard: IP66/67, Type 4X enclosure |
| Power Supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Electromagnetic - The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity, ensuring accurate and reliable flow measurement in demanding process applications.
Send your inquiry directly to us