logo
Home > Products > Electromagnetic Flow Meter >
Proline Promag P 10 electromagnetic flowmeter

Proline Promag P 10 electromagnetic flowmeter

Proline Promag P 10 flowmeter

electromagnetic flow meter with warranty

industrial electromagnetic flow meter

Place of Origin:

Switzerland

Brand Name:

Endress+Hauser

Certification:

CE

Model Number:

Proline Promag P 10

Contact Us
Request A Quote
Product Details
Measured Variables:
Volume Flow, Conductivity, Mass Flow
Max. Process Pressure:
PN 40, Class 300, 20K
Transmitter Housing Material:
AlSi10Mg, Coated
Degree Of Protection:
Standard: IP66/67, Type 4X Enclosure
Digital Communication:
HART, MODBUS RS485
Highlight:

Proline Promag P 10 flowmeter

,

electromagnetic flow meter with warranty

,

industrial electromagnetic flow meter

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
Proline Promag P 10 Electromagnetic Flowmeter
Flowmeter for basic process applications with easy-to-use operation concept, dedicated to chemical and process applications with corrosive liquids.
Field of Application
Promag P is designed for chemical and process applications with corrosive liquids and high medium temperatures. With straightforward hardware and software design, Promag P 10 simplifies every step from engineering to servicing. Heartbeat Technology enables safe processes.
Key Benefits
  • Diverse applications with wide variety of wetted materials
  • Energy-saving flow measurement with no pressure loss due to cross section constriction
  • Maintenance-free operation with no moving parts
  • Optimum usability with mobile devices and SmartBlue app or touch screen display
  • Simple, time-saving commissioning with guided parameterization
  • Integrated verification through Heartbeat Technology
Technical Specifications
Measurement Performance
Maximum Measurement Error (Standard) ±0.5% o.r. ± 1 mm/s (0.04 in/s)
Maximum Measurement Error (Option) ±0.2% o.r. ± 2 mm/s (0.08 in/s)
Measuring Range 4 dm³/min to 9600 m³/h (1 gal/min to 44,000 gal/min)
Operating Conditions
Medium Temperature Range (PFA Liner) -20 to +150 °C (-4 to +302 °F)
Medium Temperature Range (PTFE Liner) -40 to +130 °C (-40 to +266 °F)
Maximum Process Pressure PN 40, Class 300, 20K
Materials & Construction
Wetted Materials - Liner PFA; PTFE
Wetted Materials - Electrodes 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Nominal Diameter Range DN 15 to 600 (½ to 24")
Electrical & Communication
Power Supply DC 24 V, AC 100-230 V, AC 100-230 V / DC 24 V (non-hazardous area)
Digital Communication HART, MODBUS RS485
Outputs 4-20 mA HART (active/passive), Pulse/frequency/switch output, Modbus RS485
Approvals & Certifications
Hazardous Area: ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, IND Ex, KC, JPN, UK Ex
Metrological: ISO/IEC 17025, ISO 9001:2015
Pressure: PED, CRN
Hygienic: ACS; NSF61, WRAS

Send your inquiry directly to us

Privacy Policy China Good Quality Water Quality Sensor Supplier. Copyright © 2018-2025 Xi'an Kacise Optronics Co.,Ltd. . All Rights Reserved.