Place of Origin:
China
Brand Name:
KACISE
Model Number:
KUW3000-C
Ultrasonic flowmeter is a kind of non-contact instrument, it can be used to measure the medium flow of large diameter and can be used to measure the medium that is not easy to contact and observe. Its measuring accuracy is very high, the highest clamp installation can also reach the accuracy of ±0.5%, almost free from the interference of various parameters of the measured medium, especially can solve the other meters can not be strong corrosive, non-conductive, radioactive and inflammable and explosive media flow measurement problems.
Dual-channel design, reliable and stable measurement.
High accuracy within ±1%
Based on GPRS and RF design, multiple signal output, achieving remote monitoring.
Achieve heat measurement by connecting heat transducers GXPS100.
Ultrasonic flowmeter can be used to measure the flow rate of chemical liquids, water, oil and other liquids, application scenarios are generally chemical factories, sewage treatment plants, water plants, steel mills, food processing plants, cleaning machines, kitchens, domestic water and so on. As long as liquid flow is used, and there is a need to know the flow data of the pipeline, need to use the flowmeter.
![]()
![]()
![]()
| Item | Specification |
|---|---|
| Standard | ISO4064-2005, GBT778-2007 |
| Measurement Liquid |
Water, sewage, seawater(other liquid need to customized) liquid should be full of pipeline |
| Medium Temperature | 0.1~30 ℃ |
| Working Environment | Temperature: -10~45 ℃; Humidity ≤100%(RH) |
| Working Pressure | 1.6MPa(2.5MPa optional) |
| The sensitivity of upstream | U3 |
| THe sensitivity of downstream | D0 |
| Climatic and mechanical | C Class |
| Electromagnetic compatibility class | E2 Class |
| Communication Interface | RS485/USART/Infrared |
| Output Signal | 2 way OCT pulse output/TTL pulse output/One way 4~20mA output |
| Power supply | Built-in Lithium battery(3.6,19AhV)/DC8~36V power supply |
| Protection Class | IP68, can work 2 meters under water |
| Digital Display |
Multi line 9 digital accumulative flow, 4 digital display for instantaneous flow, varies of state prompt and units. |
| Data Storage | EEPROM/FLASH, automatically record the accumulative flow of last 512 days |
| Measurement cycle | Measuring: 1 times/second; Verification: 4 times/second |
| Power Consumption | 10 years battery life |
| Nominal Diameter |
R | Flow(m3/h) | ||||
|---|---|---|---|---|---|---|
| Starting Flowrate |
Minimum Flowrate Q1 |
Transitional Flowrate Q2 |
Permanent Flowrate Q3 |
Overload Flowrate Q4 |
||
| DN15 | 200 | 0.003 | 0.0125 | 0.020 | 2.500 | 3.125 |
| DN20 | 200 | 0.0035 | 0.016 | 0.026 | 3.200 | 4.000 |
| DN25 | 200 | 0.007 | 0.020 | 0.032 | 4.000 | 5.000 |
| DN32 | 200 | 0.010 | 0.032 | 0.050 | 6.300 | 7.875 |
| DN40 | 200 | 0.015 | 0.100 | 0.160 | 20.000 | 25.000 |
| DN50 | 100 | 0.030 | 0.400 | 0.640 | 40.000 | 50.000 |
| DN65 | 100 | 0.059 | 0.630 | 1.008 | 63.000 | 78.750 |
| DN80 | 100 | 0.064 | 1.000 | 1.600 | 100.000 | 125.000 |
| DN100 | 100 | 0.094 | 1.600 | 2.560 | 160.000 | 200.000 |
| DN125 | 100 | 0.120 | 2.000 | 3.200 | 200.000 | 250.000 |
| DN150 | 100 | 0.270 | 2.500 | 4.000 | 250.000 | 312.500 |
| DN200 | 100 | 0.315 | 4.000 | 6.400 | 400.000 | 500.000 |
| DN250 | 100 | 0.508 | 4.000 | 6.400 | 400.000 | 500.000 |
| DN300 | 100 | 0.770 | 6.300 | 10.080 | 630.000 | 787.500 |
![]()
![]()
KACISE designs and manufactures a full line of high accurated ultrasonic flow meters, ultrasonic water meters and ultrasonic heat meters. An innovator in ultrasonic flow measurement and control products, Measuring water, oil, chemicals and other fluids. KACISE products are well known for accuracy, long-lasting durability and for providing valuable and timely measurement data.