Product Details:
Place of Origin: China
Brand Name: KACISE
Certification: CE
Model Number: KUF2000 Series
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: Negotiable
Packaging Details: one carton for one set
Delivery Time: 3-5 work days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 1000 sets per month
Contact Now
Detailed Product Description
Pipe Diameter: DN15~6000mm Communication: RS485 Modbus
Pipe Material: Steel, Stainless Steel, Cast Iron, Copper, Cement Pipe, PVC, Aluminum, Glass Steel Product, Liner Is Allowed Signal Output: 4-20mA, OCT Pulse, Relay
Power Supply: DC8~36V Or AC85~265V Or Battery Medium: Water, Sea Water, Waste Water, Oil, Chemicals (alcohol, Acids, Etc.), Beverage (beer, Wine, Etc.)...
High Light:

ultrasonic flow transducer

,

ultrasonic liquid flow meter

Sanitary Hygienic Type Food Grade Vegetable Oil / Milk / Beer Flow Meter

 

 

 

Introduction

 

 

The KUF2000 series ultrasonic water flow meter is a reliable solution designed for long-term field measurements. It offers flexibility with three types of sensors to measure pipe flow: clamp on type, insertion type, and inline pipe type. Additionally, this flow meter can measure heat when equipped with a temperature sensor, providing comprehensive data for various applications. An optional SD card feature allows for the storage of large quantities of data, ensuring efficient monitoring and analysis.

 

Clamp On Type: This sensor type clamps onto the outside of pipes without direct contact with the internal liquid. All models can function as energy meters when connected to temperature sensors. The KUF2000 Series Clamp On Ultrasonic Flowmeter ensures easy installation without the need to cut off the pipe or interrupt water flow, making it suitable for long-term online measurements. It can accurately measure a wide range of liquid flows with the sensor clamped onto the pipe.

 

Insertion Type: Requiring only two installation holes on the pipe, insertion type sensors are easy to install. The hole-making tool facilitates a no-stop-flow installation. These sensors come in direct contact with the fluid, ensuring stable and reliable measurements.

 

Inline Pipe Type: For DN15-32mm pipes, the π shape inline pipe sensor is utilized, while DN40 and above use standard inline pipe sensors. Inline sensors offer advantages such as a low starting flow rate, high measurement accuracy, and no pressure loss, making them suitable for various applications.

 

 

Parameters 

  

 

 

 

 

 

 

 

Host part

Principle

Ultrasonic time gap

Accuracy

±1%

Display

2×20 character LCD with backlight

 

Signal output

1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0. 1%

1 way OCT pulse output( Pulse width 6 ~ 1 0 0 0 ms,default is 2 0 0 ms)

1 way Relay output

 

Signal input

3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as temperature, press and liquid level

Connect the temperature transducer Pt100, can finish the heat/energy measurement

Data interface

Insulate RS485 serial interface, upgrade the flow meter software by computer, support the MODBUS, METER-BUS etc.

Cable

Twisted-pair cable, generally, the length under 50 meters;

Select the RS485 communication. The transmission distance can over 1000m.

 

 

Pipe Condition

Pipe material

Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed.

Pipe Diameter

DN15~6000mm

Straight length pipe

Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump.

 

 

Medium

Type of Liquid

 Water, sea water, waste water, oil, chemicals (alcohol, acids, etc.), plant effluent and other liquids

Temperature

-30~160°C

Turbidity

10000pm not so much bubbles

Flow speed

0~±10m/s

Environment

Temperature

Host: -20~60°C; Sensor: -30~160°C

Humidity

Host: 85%RH;  Flow sensor: IP68, less than 2m under water

Power supply

DC8~36V or AC85~265V or Battery

Consumption

1.5W

Hygienic Sanitary Flow Meter , Vegetable Oil / Milk Food Grade Flow Meter 0

Sensor Selection

 

Hygienic Sanitary Flow Meter , Vegetable Oil / Milk Food Grade Flow Meter 1

 

Optional Temp. sensor

 

Hygienic Sanitary Flow Meter , Vegetable Oil / Milk Food Grade Flow Meter 2

 

Optional Host

 

Hygienic Sanitary Flow Meter , Vegetable Oil / Milk Food Grade Flow Meter 3

 

Ordering Infomation

 

Hygienic Sanitary Flow Meter , Vegetable Oil / Milk Food Grade Flow Meter 4

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Other Products

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.