Place of Origin:
China (Mainland)
Brand Name:
Kacise
Model Number:
KUS series
| 型号:KUS630 | |
|---|---|
| Measuring range | 0.6m... 10m |
| Blind spot | 0 ... 0.6m(Unstable working area is within 0.6m, it is not recommended to work in this range); the minimum blind area version of 0.3m can be achieved, which needs to be customized. |
| Supply voltage | 3.3 ... 24 V DC , ripple 10 %SS |
| Working current |
≤ 45 mA (fastest measurement speed) Low-power version, sleep power consumption is less than 0.3mA, sending power consumption is 20mA (less than 2ms), and receiving power consumption is not more than 8mA (less than 150ms) |
| Output signal |
|
| Measurement accuracy | ≤1 % |
| Temperature compensatin | yes |
| Line order | Colour | Definition |
|---|---|---|
| 1 | Red | Power is positive |
| 2 | Black | power return ground |
| 3 | Yellow | Analog output, voltage output, current output switch output |
| 4 | Blue | RS485 A+ or uart TXD |
| 5 | Green | RS485 B- or uart RXD |
![]()
![]()
analog
The analog output can be set through RS485, and the sensor can work in 8 modes. The specific reference is as follows:
8 working modes of the sensor.
485 output data
485 output data is in MODBUS-RTU format. Refer to the software instruction manual for details.
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
| KUS | Body size | OUTPUT | Max range | Description | |
|---|---|---|---|---|---|
| 600 | |||||
| Customized | Customized | ||||
| 4-20mA | 4-20mA mode output with RS485 MODBUS protocol | ||||
| 0-3.3V | The power supply range is 3.3 at least | ||||
| 0-5.0V | The power supply range is 5.0 at least | ||||
| RS485 | Power save mode with RS485 MODBUS protocol | ||||
| XX m | XX m is the maxim range can be detected, the default length is 1 meter | ||||
| KUS | 600 | RS485 | 3m | ||
![]()
Send your inquiry directly to us