Send Message
Home ProductsUltrasonic Transducer Sensor

200Kbs Ultrasonic Tank Level Sensor Axial Installation For Oil Industry

200Kbs Ultrasonic Tank Level Sensor Axial Installation For Oil Industry

  • 200Kbs Ultrasonic Tank Level Sensor Axial Installation For Oil Industry
200Kbs Ultrasonic Tank Level Sensor Axial Installation For Oil Industry
Product Details:
Place of Origin: China
Brand Name: Kacise
Model Number: KUS650
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: Negotiable
Packaging Details: carton/wooden case, or customers requests
Delivery Time: 5-8 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal
Supply Ability: 10000pcs/month
Contact Now
Detailed Product Description
Certification: CE Brand: Kacise
Model: KUS650 Protection: IP65 ,conform To EN 60529
Name: Ultrasonic Tank Level Sensor Applied For: Fire Water System
High Light:

200Kbs Ultrasonic Tank Level Sensor

,

LCD Display Ultrasonic Tank Level Sensor

,

IP65 Ultrasonic Tank Level Sensor

KUS650 ultrasonic tank level sensor

 

Application field

 

• Fire water system.

• City water supply.

• Sewage treatment.

• Long distance heating supply.

• Food industry.

• power chemical or oil industry.

 

Product features
Power supply: two DC3.6V disposable lithium batteries
Wireless transmit power: <23 dBm
Receiving sensitivity: <-135 dBm
Theoretical bandwidth: 200Kbs
Support wireless transmission of alarm status to server, server address and port can be configured
Adopt precision digital temperature compensation and nonlinear correction technology, wide temperature range and full range precision compensation;
A variety of data type indication (percentage, output current display);
Special wide temperature LCD display (-30℃~80℃);
Provide multiple power supply methods at the same time;
Vertical installation or axial installation, providing a variety of liquid level/level interface and interface materials;
With parameterized LCD and three setting buttons.
According to user needs and site conditions, the collection frequency and collection time interval can be set.
Battery power monitoring, when the power is low, the meter screen flashes and prompts to report to the centralized management platform at the same time.
Water pressure/water level alarm threshold can be set and modified according to actual needs.
Automatic alarm for water pressure/water level alarm threshold.

 

Technical parameters

 

Enter
Measured variable Liquid

level, material level

 

Maximum measuremen trange

1.2-30m (can be customized according to demand)

 

Output
Comprehensive accuracy ±0.15%FS/ 0.15℃
Temperature compensation -10℃~70℃
Vibration effects < ± 0.05%/g, 500Hz in all directions (according to IEC 68-2-64)

Rated conditions

environmental conditions

Ambient temperature -25~+85℃
Storage temperature -40~+85℃
Protection class IP68 , according to EN 60529
Electromagnetic Compatibility EN 61326/A2 Annex A (2001)
Display and control
Display SFTN liquid crystal, white backlight, 5-digit display.
Limit value Free setting
Parameter setting Use 3 buttons
Unit

The unit is mm, and the default unit is m.

 

Weight

about 1.35kg

 

Materials of non-wetted parts
Joint 1NPT, stainless steel, length 20mm (material and joint specifications can be customized according to customer requirements).
Electrical connection

Make waterproof connector, air vent cable entry according to EN 175301-803A standard

 

Measurement period ≤ 100ms

Selection Tips: For special requirements, please contact our company and indicate it in the order.

parameter settings

 

1. Send time setting

Opcode: 2121 units (minutes)

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2121"; press the "M" key to confirm, Display "S_TIM", press "M" key, display "00000" (the last set value,), set the value (range 1) by "up" key (data left shift key) and "down" key (data increase key) ~09999), after the adjustment is completed, press the "M" key to confirm and save.

2. Collection time interval setting

Opcode: 2122 units (seconds)

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2122"; press the "M" key to confirm, Display "S_FrE", press "M" key, display "00000" (the last set value,), set the value (range 1~09999) by "up" key and "down" key, press "M" after adjustment is completed key to confirm saving.

3. Data upload method setting

Opcode: 2124

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2124"; press the "M" key to confirm, Display "S.MOdE", press "M" key, display "last set value", use "up" key and "down" key to set, after adjustment is completed, press "M" key to confirm and save.

4. Alarm interval time setting

Opcode: 2125 units (minutes)

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2125"; press the "M" key to confirm, Display "S_ErT", press "M" key, display "00000" (the last set value,), set the value (range 1~09999) by "up" key and "down" key, press "M" after adjustment is completed key to confirm saving.

5. Liquid level/level alarm upper limit setting

Opcode: 2311

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2311"; press the "M" key to confirm, Display "Ad1H", press "M" key to set the upper limit alarm value, set the value by "up" key and "down" key, "Ad1F" alarm upper limit hysteresis value, "Ad1d" alarm upper limit delay, all adjustment Press the "M" key to confirm saving when finished.

6. Liquid level/level alarm lower limit setting

Opcode: 2312

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2312"; press the "M" key to confirm, Displays "Ad2H", press the "M" key to set the upper limit alarm value, use the "Up" and "Down" keys to set the value, "Ad2F" alarm upper limit hysteresis value, "Ad2d" alarm upper limit delay, all adjustments Press the "M" key to confirm saving when finished.

7. Instrument zero calibration

Opcode: 1000

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "1000"; press the "M" key to confirm, Display "bd_0" Press the "up and down" keys to select "NO (exit without calibration) or YES (calibration zero)". Press the "M" key to confirm saving and exit.

8. Instrument zero point removal

Opcode: 1511

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "1511"; press the "M" key to confirm, Display "CUTO", press the "M" key, it will display "00000" (the last set value), use the "up" and "down" keys to set the value (range 1~29999), press "M" after the adjustment is completed key to confirm saving.

9. Meter offset setting

Opcode: 1510

In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "1510"; press the "M" key to confirm, Display "OFSET", press "M" key, display "00000" (the last set value,), set the value (range -19999~29999) by "up" key and "down" key, press "M" after adjustment is completed " button to confirm saving.

 

 

Storage and transportation

1. The product should be stored at -40℃~+80℃, relative humidity not more than 90%, ventilated, dry, and non-corrosive gas warehouse.

2. The product is packed in the same package with the certificate and instruction manual. Strong collisions are strictly prohibited during transportation.

Note: The contents of the manual are subject to change without notice, please pay attention to keep in touch.

 

 

Company information

Xi'an Kacise Optronics Co., Ltd. was founded in 2000, is located in Xi'an, Shaanxi Province, China, is a professional engaged in instrumentation and sensors, R & D, production, sales as one of professional high-tech enterprises, we have our own production workshop and central laboratory. Factory building area is about 3000 square meters, with production of more than 30 employees, 8 engineer, 6 inspectors, 10 saleman, 5 for customer service, is this industry, we are one of the strong technology manufacturers with varieties specification.

 

When the company set up, we began to focus on the coordination of military supplies production, achieved GB/T19001-2008/ISQ9001:2008, GJB 9001B-2009 certification. When our company is running mature and stable, in 2008, we began to develop our business. Based on the production of military products quality control, we developed a lot of sensor products, such as a pressure sensor / transducer / sensor, level transmitter / ultrasonic level meter / ultrasonic flow meter, inertial navigation products, IMU, gyroscope, accelerometer etc.

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.