Place of Origin: | China (Mainland) |
Brand Name: | KACISE |
Certification: | certificate of explosion-proof, CE |
Model Number: | KSCH4 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Delivery Time: | 5-8 work days |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 1000 Pieces per Week |
Sensor Type: | Infrared Principle | Measurement Accuracy: | ± (500PPM+5%reading) |
---|---|---|---|
Measurement Range: | 0 ~ 50000PPM Can Be Customized | Resolution: | 100PPM |
Repeatability: | 2.5% | Response Time (T90): | <30s |
Calibration: | Standard Calibration | Signal Output: | Serial IIC PWM Analog Output (0.4-2V) |
Power Supply Source: | 5VDC±5% | Current Range: | Current Range |
Work Environment: | Temperature -20... + 50 ℃ Humidity 0... 95%RH, No Condensation | Storage Environment: | Temperature -20... + 80 ℃ Humidity 0... 95%RH, No Condensation |
High Light: | Stable Performance Methane Sensor,100PPM Methane Sensor,High Accuracy Methane Sensor |
KSCH4 Methane sensor manual
Introduction
KSCH4 is a based on NDIR non-dispersed infrared absorption principle of gas detection module, adopt the dispersive air inlet. KSCH4 using porous inner light tube and casing outside the card slot, not only ensure the characteristics of air convection diffusion speed, and strong and durable, easy to install.
KSCH4 uses an imported light source and a dual-channel detector. Has the very good selectivity, no oxygen dependence, long life characteristics.
KSCH4 with UART, IIC digital output and analog output voltage (or the PWM frequency output mode), facilitating the clients to choose application; KSCH4 provide zero calibration, calibration and sensitivity of clean air relative zero calibration command, and to provide customers a manual clean air relative zero calibration MCDL pin, convenient to customers in the use of the free flow of clean outdoor air relative zero calibration of sensor module.
Feature
Dimension
Application
Technical Specifications
Parameters | Technical Indicators |
Sensor type | Infrared Principle |
Measurement accuracy | ± (500PPM+5%reading) |
Measurement range | 0 ~ 50000PPM can be customized |
Resolution | 100PPM |
Repeatability | 2.5% |
Response time (T90) | <30s |
Calibration | Standard Calibration |
Signal output | Serial IIC PWM analog output (0.4-2V) |
Power supply source | 5VDC±5% |
Current range | 150mA |
Work environment |
Temperature -20... + 50 ℃ Humidity 0... 95%RH, no condensation |
Storage environment |
Temperature -20... + 80 ℃ Humidity 0... 95%RH, no condensation |
Installation
Installation instructions:
1.Wiring according to the electrical wiring diagram.
2. After confirming that the wiring is correct, please install it according to the on-site conditions.
3.After the installation is completed, please carry out the power test in the specified power supply range.
Wiring
Terminal definition | |||
Pin | Function | Pin | Function |
1 | Power supply positive electrode | 1 | I2C- SCL |
2 | Power negative electrode | 2 | I2C- SDA |
3 | Serial port reception | 3 | PWM/DA |
4 | Serial port sending | 4 | MCDL |
Note: MCDL - Clean Air relative to calibration function pin