Place of Origin:
China
Brand Name:
KACISE
Certification:
CE
Model Number:
KUF100
KUF100 Ultrasonic Flow Meter
Feature
Technical Specifications
Supported Pipe Materials | stainless steel, iron, brass, aluminum, PVC, PP, PVDF and other rigid plastic pipes |
Supported Liquid Medium | Water or other (single without solid particles and impurities) |
Supported Medium Temperature | 0-75°C (no freezing on the surface, high temp, version customizable) |
Default Low Flow Cutoff | 0.1m/s |
Display Method | 256*128 backlit LCD |
Response Time | 0.5~60s |
Accuracy Class | ±2%, up to ±1% after calibration |
Data Storage Period | 300 milliseconds |
Memory Backup | EEPROM (data storage length: more than 10 years, data read/write frequency: more than 1 million times) |
Power And I/O Connectors | M12 aviation plug |
Output | 4-20mA |
Communication | Modbus RS485 |
Optional Output | OCT (pulse output) / one relay alarm |
Power Supply | 10-24V VDC |
Electric Power | <3W |
Circuit Protection | Power reverse protection, power surge protection |
Each output short-circuit protection, each output surge protection | |
Protection Level | IP65 |
Ambient Temperature | -10 to 60°C (no freezing) |
Relative Humidity | 35 to 85% RH (non-condensing) |
Vibration Resistance | 10 to 55 Hz, double amplitude 1.5mm, 2 hours each for XYZ axes |
Impact Resistance | 100m/s2 16 ms pulse, X, Y, Z axis each 1000 times |
Meter Material | aluminum alloy, industrial plastic |
Cable Length | Standard 2 meters, (PT1000 standard 9 meters) |
Flow Range
Pipe diameter | Upper limit flow value ( L/min ) |
15 | 60 L/min |
20 | 100 L/min |
25 | 200 L/min |
32 | 300 L/min |
40 | 400 L/min |
50 | 600 L/min |
65 | 1000 L/min |
Dimensions
DN15-40
DN50-65
Ordering Information
Code | Definition |
Pipe diameter: DN15-DN65mm | |
Range: 0.03m/s-10m/s | |
Accuracy: ±2% (1% after calibration) | |
Measurement medium: water/other (single without solid particles and impurities) | |
Power supply: 10~24VDC/1A | |
Sensor operating temperature: 0-115℃; | |
Other: 2 meters of cable as standard | |
Heat meter: with a pair of PT1000 temperature sensors; one end of the temperature sensor is on the meter, and the other end of the cable is standard 9m | |
Pipe Diameter | |
S | DN15-DN40 |
T | DN50-DN65 |
Meter Type | |
1 | Ultrasonic flow meter |
2 | Ultrasonic cold (heat) meter |
Sensor Type | |
C2 | 0-65°C |
C2U | 0-115°C |
Output (can choose two out of four) | |
A | 4-20mA |
M | Modbus |
O | OCT (Frequency) |
R | 1 Relay |
PT1000 Temperature Sensor Cable Length | |
P | Temperature sensor cable length at the other end 9m |
P(15) | Temperature sensor cable length at the other end 15m |
P(25) | Temperature sensor cable length at the other end 25m |
Send your inquiry directly to us