KTG181 Cement Kiln Process Analysis Complete System
Introduction
The high-temperature sampling probe used in the KTG181 cement kiln process analysis complete system is a new practical dry-process high-temperature sampling probe developed by our company (which can replace the dry-process high-temperature probe of Siemens, Germany). It has been successfully applied to many cement production industries for several times and has received a great deal of praise from users.
Technical Configuration Plan for the Complete Set System of Cement Kiln Process Analysis
Serial Number | Complete Set System Name | Detection Point | Purpose | Gas - sample Conditions | Measured Components | Selected Measuring Range | Remarks | |
1 | (KTG181- 01 Type) Kiln - end Process Analysis Complete Set System | Kiln end | Optimization control | Temperature: 1100 - 1300℃, Dust: 200g/m³ | CO,O₂,NO | 0 - 2%,0 - 10%,0 - 2000ppm | Process selection 2 parameters: Detect NO. | |
2 | (KTG181- 02 Type) Calciner Process Analysis Complete Set System | Outlet of C₅ (the fifth-stage cyclone) at the inlet of the calciner | Optimization control | Temperature < 900℃, Dust < 80g/m³ | CO,O₂ | 0 - 2%,0 - 10% | ||
3 | (KTG181- 03 Type) Preheater Process Analysis Complete Set System | Outlet of C₁ (first - stage cyclone) of the preheater or inlet of the high - temperature fan | Optimization control | Temperature < 450℃, Dust < 80g/m³ | CO,O₂ | 0 - 2%,0 - 10% | Either the calciner system or the preheater system can be optionally selected. | |
4 | (KTG181-04 Type) Electrostatic Precipitator Process Analysis Complete Set System | Kiln - end Electrostatic Precipitator Complete Set System | Inlet of the kiln - end electrostatic precipitator | Safety monitoring | Temperature < 160℃, Dust < 80g/m³ | CO | 0 - 2% | The probe adopts an uninterrupted and fast return circuit design to ensure the safe operation of the electrostatic precipitator. |
Coal Mill Electrostatic Precipitator Complete Set System | Outlet of the coal mill electrostatic precipitator | Safety monitoring | Temperature < 80℃, Dust < 40g/m³ | CO | 0 - 2000ppm | |||
Kiln - end Bag Filter Outlet Complete Set System | Outlet of the kiln - end bag filter | Safety monitoring | Temperature < 80℃, Dust < 100mg/m³ (Outlet) | CO | 0 - 2% | |||
Coal Mill Bag Filter Complete Set System | Outlet / inlet of the coal mill bag filter | Safety monitoring | Temperature < 80℃, Dust < 100mg/m³ (Outlet), Dust < 600g/m³ (Inlet) | CO | Deviation value: 0.5%, Absolute value: 2% | 1.When using a single - probe scheme, only measure at the outlet. 2.Using complete set systems at the outlet and inlet respectively is more conducive to ensuring safety. |
||
Wet - process Cement Electrostatic Precipitator Complete Set System | Inlet of the wet - process cement electrostatic precipitator | Safety monitoring | Temperature < 200℃, Dew point < 70℃, Dust < 60g/m³ | CO | 0 - 2% | When sampling is carried out in the settling chamber in advance, optimization control can be implemented. | ||
5 | (KTG181-05 Type) Coal Powder Bunker Process Analysis Complete Set System | Coal powder bunker | Safety monitoring | Temperature < 45℃, Dust < 80g/m³ (during dust raising) | CO | 0 - 0.5% |