Product Details
Operating Voltage And Power Consumption:
DC24V ± 6V, ≤ 1.5W (DC24V)
Detection Range:
Diffusion Type
Communication Distance:
≤ 1000m (RVSP1.5mm²)
Electrical Interface:
G3/4" Internal Thread
Explosion - Proof Mark And Protection Level:
Ex Db IIC T6 Gb : Ex Db IIIC T80°C Db IP66
Operating Temperature And Humidity:
-40°C - +70°C, ≤ 93%RH
Highlight:

Industrial Point-type Combustible Gas Detector

,

KAN103 Point-type Combustible Gas Detector

,

Commercial Point-type Combustible Gas Detector

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description

KAN103 Point-type Combustible Gas Detector for Industrial and Commercial Use

 

Product Introduction

The detector is compatible with various types of gas sensors, including catalytic, infrared, semiconductor, and electrochemical sensors. The housing is designed with a thickened explosion-proof aluminum alloy, ensuring long-term and stable operation in all kinds of industrial explosion-proof environments.

It is an all-round detector that allows for switching between 2/3/4-wire systems, RS485, and LoRa communication by replacing plug-and-play modules. The detector comes with a switch output (passive relay output). You can adjust the output setting to follow a specific mode through parameter configuration. Additionally, it is equipped with a drive output for an audible and visual alarm (24V DC).

KAN103 Point-type Combustible Gas Detector for Industrial and Commercial Use 0

 

Product Description

 

Operating Voltage and Power Consumption Detection Range Detection Principle Communication Distance
DC24V ± 6V, ≤ 1.5W (DC24V) Diffusion type Catalytic combustion, Electrochemical, Infrared, PID ≤ 1000m (RVSP1.5mm²)
Electrical Interface Explosion - proof Mark and Protection Level Output Capacity Communication and Operation Modes
G3/4" internal thread Ex db IIC T6 Gb : Ex db IIIC T80°C Db IP66 1 set of passive switch output: 220VAC/24VDC, 2A
1 set of active audible and visual alarm output
Infrared remote control within ≤ 8 meters
4 - 20mA three - wire communication, ABUS four - wire system
TBUS two - wire system, RS485, LoRa communication
Alarm Value Operating Temperature and Humidity Display Method Pressure Range and Response Time
Specific parameters of different sensors are shown on the nameplate -40°C - +70°C, ≤ 93%RH Three - light status display 86KPa - 106KPa
< 30S (T90)

 