Place of Origin:
CHINA
Brand Name:
KACISE
Certification:
CE
Model Number:
KGD-ATRS-319
Technical Parameters
Items | Details |
Detection Principle | CO₂: Dual Beam NDIR (Non - Dispersive Infrared) spectroscopy absorption technology |
CO: Metal Oxide Semiconductor (MOX) gas detection technology | |
Pressure: Piezoresistive type | |
Temperature: Negative Temperature Coefficient (NTC) thermistor | |
Detection Parameters | CO₂, CO, temperature, pressure (CH₄ + H₂ can be extended and customized) |
Detection Range | CO₂: 0ppm - 10000ppm |
CO: 1 - 1000ppm | |
Air pressure: 80kPa - 120kPa | |
Temperature: -40°C - 125°C | |
Resolution | 1ppm |
Detection Accuracy | CO₂: ±(50ppm + 5% of the reading) |
CO: ±40ppm or ±30% of the reading (take the larger value) | |
Pressure: ±1kPa | |
Temperature: ±2°C | |
Data Refresh | ≤1s |
Response Time | T90 < 15s |
Output Mode | CAN/LIN/UART/analog voltage |
Operating Conditions | -40°C - +85°C; 0 - 90%RH (non - condensing) |
Storage Conditions | -40°C - 110°C; 0 - 99%RH (non - condensing) |
Supply Voltage | 9 - 16VDC, standard voltage +12VDC |
Average Operating Current | ≤100mA, @+12VDC (can activate low - power mode, supporting 24 - hour online monitoring) |
Standby Current | ≤100μA, sleep mode |
Send your inquiry directly to us