logo
Home > products > Gas Detector Sensor >
KGD - WQ - 528 Infrared Exhaust Gas Sensor Module

KGD - WQ - 528 Infrared Exhaust Gas Sensor Module

Infrared Exhaust Gas Sensor Module

KGD Exhaust Gas Sensor Module

WQ Exhaust Gas Sensor Module

Place of Origin:

CHINA

Brand Name:

KACISE

Certification:

CE

Model Number:

KGD-WQ-528

Contact Us
Request A Quote
Product Details
Resolution:
HC: 1ppm; CO₂: 0.01%; CO: 0.01%
Response Time:
T90 ≤ 3.5s (NDIR)
Communication:
RS - 232, Can Be Connected To Gasboard Series Exhaust And Smoke Analysis Equipment
Power Supply:
12V ± 0.2V, 3.2A
Highlight:

Infrared Exhaust Gas Sensor Module

,

KGD Exhaust Gas Sensor Module

,

WQ Exhaust Gas Sensor Module

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description

KGD - WQ - 528 Infrared Exhaust Gas Sensor Module

Product Introduction

The KGD - WQ - 528 Infrared Exhaust Gas Sensor Module is based on non - dispersive infrared technology for gas concentration detection, featuring high precision and fast response. The product uses a multi - element combined measurement method, enabling simultaneous measurement of multiple gases. It has optimized interference compensation internally to avoid mutual interference among the measured gases. Combined with a microcontroller for processing, it performs functions such as gas sampling signal processing, sensor zero - adjustment, calibration, and result output. It realizes fast and accurate measurement of gases with multiple combined concentrations, meeting the requirements of automated measurement systems.

KGD - WQ - 528 Infrared Exhaust Gas Sensor Module 0

Product Features

  • Adopts high - precision infrared dual - beam sensor technology, capable of measuring CO, CO₂, and HC.
  • Equipped with O₂ and NO measurement interfaces, enabling integration with other exhaust gas analysis equipment.
  • Automatic constant - temperature heating, temperature, and pressure correction.
  • Modular sensor design for easy integration.
  • Long service life, low cost, and high cost - performance ratio.

Technical Parameters

Gas Type Measuring Range Absolute Error Relative Error
HC (0 - 2000)×10⁻⁶ ± 4×10⁻⁶ ± 3%
(2001 - 5000)×10⁻⁶ -- ± 5%
(5001 - 9999)×10⁻⁶ -- ± 10%
CO (0.00 - 10.00)×10⁻² ± 0.02×10⁻² ± 3%
(10.01 - 14.00)×10⁻² -- ± 5%
CO₂ (0.0 - 16.0)×10⁻² ± 0.3×10⁻² ± 3%
(16.01 - 18.0)×10⁻² -- ± 5%
Note Meeting either the absolute error or relative error requirement in the table is acceptable.
Resolution HC: 1ppm; CO₂: 0.01%; CO: 0.01%
Response Time T90 ≤ 3.5s (NDIR)
Communication RS - 232, can be connected to Gasboard series exhaust and smoke analysis equipment
Power Supply 12V ± 0.2V, 3.2A