logo
Home > Products > Electromagnetic Flow Meter >
Flow-X flow computer

Flow-X flow computer

Flow-X electromagnetic flow meter

Flow-X flow computer with warranty

industrial electromagnetic flow meter

Place of Origin:

Switzerland

Brand Name:

Endress+Hauser

Certification:

CE

Model Number:

Flow-X

Contact Us
Request A Quote
Product Details
Measuring Variables:
Gas Volume Conversion, Event Logging, Parameter Logging, And Reports
Number Of Applications:
Support Up To 4 Gas Runs Or 2 Liquid Runs Per Module (Flow-X/M, Flow-X/C)
Electrical Connection:
Voltage24 V DC (± 10%), With Redundant ConnectionsCurrent Consumption:Flow-X/P0, X/M, X/S: ≤ 0.4 A Nominal; ≤ 0.8 A MaximalFlow-X/C: ≤ 0.6 A Nominal; ≤ 1.0 A Maximal
Ambient Temperature Range:
Flow-X/S: -40 °C ... +75 °CFlow-X/C, Flow-X/P, Flow-X/R: 0 °C ... +60 °C
Highlight:

Flow-X electromagnetic flow meter

,

Flow-X flow computer with warranty

,

industrial electromagnetic flow meter

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
Flow-X Flow Computer
The Flow-X flow computer provides gas volume conversion, event logging, parameter logging, and reports using state-of-the-art technology. Identical modules are combined in different housings, offering multi-stream capabilities for various installation requirements.
Key Applications
  • Custody transfer gas metering
  • Natural gas and process gas applications
  • Integration with FLOWSIC600 ultrasonic gas flowmeters
Device Variants
  • Flow-X/P: Multi-stream version for 1-4 measuring distances with local touch screen
  • Flow-X/S: Compact version for smaller installations with one measuring distance
  • Flow-X/M and Flow-X/C: Modular configurations
Technical Specifications
Inputs
6x Analog Transmitter Inputs:
  • Input types: 4-20 mA, 0-20 mA, 0-5 V, 1-5 V
  • Accuracy: 0.002% FS at 21°C, 0.008% at 0-60°C
  • Long-term stability: 0.01% per year
  • Resolution: 24 bits
16x Digital Status Inputs:
  • Resolution: 100ns (10MHz)
Outputs
4x Analog Outputs:
  • For process outputs and flow/pressure control
  • Resolution: 14 bits, 0.075% FS
16x Digital Outputs:
  • Open collector design
  • Rating: 100mA @24V
System Architecture
  • CPU and Memory: 800 MHz, 512 MB RAM, 1 GB flash memory
  • Real-time clock with accuracy better than 1 sec/day
  • Gold cap for date and time retention
  • Hardware and software watchdog timer
  • Mechanical tamper switch for parameter protection
Calculation Standards
Gas Property Calculations:
  • AGA 5, AGA 8 Part 1, AGA 8 Part 2 (GERG-2008), AGA 10
  • AGA NX-19, GERG-2008, GERG91mod
  • GOST 30319.2-1996, GOST 30319.2-2015
  • GSSSD MR-113, ISO 6976, ISO 12213
  • S-GERG
Flow Rate Calculations:
  • AGA 3, AGA 7, AGA 9, AGA 11
Operational Parameters
Parameter Specification
Number of Applications Supports up to 4 gas runs or 2 liquid runs per module
Voltage 24 V DC (±10%) with redundant connections
Current Consumption Flow-X/P0, X/M, X/S: ≤ 0.4 A nominal; ≤ 0.8 A maximal
Flow-X/C: ≤ 0.6 A nominal; ≤ 1.0 A maximal
Ambient Temperature Flow-X/S: -40°C to +75°C
Flow-X/C, Flow-X/P, Flow-X/R: 0°C to +60°C
Certifications & Approvals
  • 2014/32/EU Measuring Instruments Directive (MID)
  • 2014/30/EC Electromagnetic Compatibility
  • 2012/19/EU WEEE Directive
  • 2011/65/EU RoHS
  • OIML R117-1
  • WELMEC 7.2, 8.3, 8.8
  • API 21.1
  • Hazardous Area Approvals (Flow-X/M and X/S only)
Key Benefits
  • Reduced planning and installation costs through standard configurations
  • Very accurate volume conversion with multiple calculation cycles per second
  • High reliability through independent modules with dedicated volume conversion
  • Easy system extension with 100% software configuration
  • Reduced service costs with tamper-proof remote maintenance
  • Cost-efficient integration of multiple streams
Supported Gas Chromatographs
Supports all common gas chromatographs including ABB NGC8200 series, ABB BTU8100, Danalyser, Yamatake HGC, Encal 3000, Angus GQA, Siemens Maxum, and Sitrans.

Send your inquiry directly to us

Privacy Policy China Good Quality Water Quality Sensor Supplier. Copyright © 2018-2025 Xi'an Kacise Optronics Co.,Ltd. . All Rights Reserved.