logo
Home > Products > Electromagnetic Flow Meter >
Proline Promag W 10 electromagnetic flowmeter

Proline Promag W 10 electromagnetic flowmeter

Proline Promag W 10 flowmeter

electromagnetic flow meter with warranty

industrial electromagnetic flow meter

Place of Origin:

Switzerland

Brand Name:

Endress+Hauser

Certification:

CE

Model Number:

Proline Promag W 10

Contact Us
Request A Quote
Product Details
Measured Variables:
Volume Flow, Conductivity, Mass Flow
Max. Measurement Error:
Volume Flow (standard): ±0.5 % O.r. ± 1 Mm/s (0.04 In/s)
Measuring Range:
0.5 M3/h To 263000 M3/h (2.5gal/min To 1665 Mgal/d)
Ambient Temperature Range:
-40 To 60°C (-40 To 140°F)
Transmitter Housing Material:
Polycarbonat; AlSi10Mg, Coated
Highlight:

Proline Promag W 10 flowmeter

,

electromagnetic flow meter with warranty

,

industrial electromagnetic flow meter

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
Proline Promag W 10 Electromagnetic Flowmeter
Flowmeter for basic water and wastewater applications with easy-to-use operation concept. Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss. Suitable for elementary measurement tasks such as raw water intake.
Field of Application
Thanks to its international approvals (including drinking water certifications), the Promag W serves a wide variety of applications. Available in both compact and remote versions, it features straightforward hardware and software design that simplifies every step from engineering to servicing at Endress+Hauser quality standards. Heartbeat Technology enables measurement reliability and compliant verification.
Key Applications
  • Bidirectional measuring principle virtually independent of pressure, density, temperature and viscosity
  • Suitable for elementary measurement tasks such as raw water intake
  • International drinking water approvals
  • Degree of protection IP68 (Type 6P enclosure)
  • System integration with HART, Modbus RS485
  • Flexible operation with app and optional display
Key Benefits
  • Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss
  • Flexible engineering - sensor with fixed or lap-joint process connections
  • Application fitness - EN ISO 12944 corrosion protection for underground or underwater installation
  • Improved plant availability - sensor compliant with industry-specific requirements
  • Optimum usability - operation with mobile devices and SmartBlue app or display with touch screen
  • Simple, time-saving commissioning - guided parameterization in advance and in the field
  • Integrated verification - Heartbeat Technology
Technical Specifications
Measuring Principle Electromagnetic
Nominal Diameter Range DN 25 to 3000 (1 to 120")
Measured Variables Volume flow, conductivity, mass flow
Maximum Measurement Error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measuring Range 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1,665 Mgal/d)
Maximum Process Pressure PN 40, Class 300, 20K
Temperature Ranges
Medium Temperature Hard rubber liner: 0 to +80 °C (+32 to +176 °F)
Polyurethane liner: -20 to +50 °C (-4 to +122 °F)
PTFE liner: -20 to +90 °C (-4 to +194°F)
Ambient Temperature -40 to 60°C (-40 to 140°F)
Wetted Materials
Liner Materials Hard rubber: 0 to +80 °C (+32 to +176 °F)
Polyurethane: -20 to +50 °C (-4 to +122 °F)
PTFE: -20 to +90 °C (-4 to +160 °F)
Electrodes 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Construction Materials
Sensor Housing DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish
Transmitter Housing Polycarbonate; AlSi10Mg, coated
Electrical & Communication
Outputs 4-20 mA HART (active/passive), Pulse/frequency/switch output, Modbus RS485, 4-20 mA
Digital Communication HART, MODBUS RS485
Power Supply DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area)
Approvals & Certifications
Hazardous Area CSA, GP, KC
Metrological Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with ISO 9001:2015 requirements
Pressure CRN, PED
Material 3.1 material certificates
Hygienic Drinking water approvals: ACS, KTW-BWGL, NSF 61, WRAS BS 6920
Display & Operation
LCD display with touch & auto rotate functionality for optimal usability.
Degree of Protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3

Send your inquiry directly to us

Privacy Policy China Good Quality Water Quality Sensor Supplier. Copyright © 2018-2025 Xi'an Kacise Optronics Co.,Ltd. . All Rights Reserved.