Place of Origin:
Switzerland
Brand Name:
Endress+Hauser
Certification:
CE
Model Number:
Proline Promag W 10
| Measuring Principle | Electromagnetic |
| Nominal Diameter Range | DN 25 to 3000 (1 to 120") |
| Measured Variables | Volume flow, conductivity, mass flow |
| Maximum Measurement Error | Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) |
| Measuring Range | 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1,665 Mgal/d) |
| Maximum Process Pressure | PN 40, Class 300, 20K |
| Medium Temperature |
Hard rubber liner: 0 to +80 °C (+32 to +176 °F) Polyurethane liner: -20 to +50 °C (-4 to +122 °F) PTFE liner: -20 to +90 °C (-4 to +194°F) |
| Ambient Temperature | -40 to 60°C (-40 to 140°F) |
| Liner Materials |
Hard rubber: 0 to +80 °C (+32 to +176 °F) Polyurethane: -20 to +50 °C (-4 to +122 °F) PTFE: -20 to +90 °C (-4 to +160 °F) |
| Electrodes | 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022) |
| Sensor Housing |
DN 25 to 300 (1 to 12"): AlSi10Mg, coated DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish |
| Transmitter Housing | Polycarbonate; AlSi10Mg, coated |
| Outputs | 4-20 mA HART (active/passive), Pulse/frequency/switch output, Modbus RS485, 4-20 mA |
| Digital Communication | HART, MODBUS RS485 |
| Power Supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous Area | CSA, GP, KC |
| Metrological |
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with ISO 9001:2015 requirements |
| Pressure | CRN, PED |
| Material | 3.1 material certificates |
| Hygienic | Drinking water approvals: ACS, KTW-BWGL, NSF 61, WRAS BS 6920 |
Send your inquiry directly to us