Proline Promass H 300 Coriolis Flowmeter
Chemically resistant single-tube flowmeter with a compact, easily accessible transmitter. Highly accurate measurement of liquids and gases in applications requiring maximum corrosion resistance.
Field of Application
The highly accurate Promass H is designed for applications requiring maximum corrosion resistance and guarantees optimal safety for chemically aggressive fluids. With its compact transmitter, the Promass H 300 offers high flexibility in operation and system integration.
Key Benefits
- Maximum safety for chemically aggressive fluids with corrosion-resistant wetted parts
- Fewer process measuring points through multivariable measurement (flow, density, temperature)
- Space-saving installation with no inlet/outlet run requirements
- Full access to process and diagnostic information with numerous, freely combinable I/Os and Ethernet
- Reduced complexity and variety through freely configurable I/O functionality
- Integrated verification via Heartbeat Technology
Technical Specifications
Measuring Principle: Coriolis
Nominal Diameter: DN 8 to 50 (3/8" to 2")
Measuring Range: 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max Process Pressure: PN 40, Class 300, 20K
Measurement Accuracy
| Measurement Type |
Accuracy |
| Mass Flow (Liquid) |
±0.10% |
| Volume Flow (Liquid) |
±0.10% |
| Mass Flow (Gas, Tantalum only) |
±0.50% |
| Density (Liquid) |
±0.0005 g/cm³ |
Temperature Ranges
| Material |
Temperature Range |
| Tantalum |
-50 to +150 °C (-58 to +302 °F) |
| Zirconium |
-50 to +205 °C (-58 to +401 °F) |
| Ambient (Standard) |
-40 to +60 °C (-40 to +140 °F) |
| Ambient (Option) |
-50 to +60 °C (-58 to +140 °F) |
Wetted Materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)
Measured Variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Communication & Connectivity
Digital communication: HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Certifications & Approvals
Hazardous area: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety: CE, C-tick, EAC marking
Functional safety: IEC 61508/IEC 61511 compliant
Pressure: PED, CRN
Material: 3.1 material certificate