logo
Home > products > Precision Pressure Sensor >
Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range

Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range

Fluke 376 FC clamp meter

True-RMS clamp meter

iFlex 2500A clamp meter

Brand Name:

Fluke

Certification:

CE

Model Number:

376 FC

Contact Us
Request A Quote
Product Details
Range:
2500 A
Resolution:
0.1 A
Accuracy:
3% ±5 Digits (5 – 500 Hz)
Highlight:
2500 A Range Clamp Meter, 0.1 A Resolution Clamp Meter
Highlight:

Fluke 376 FC clamp meter

,

True-RMS clamp meter

,

iFlex 2500A clamp meter

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range
Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range 0
Key Features
  • 2500 A Range Clamp Meter
  • 0.1 A Resolution Clamp Meter
  • True-RMS measurements
  • Includes iFlex flexible current probe
Technical Specifications
Attribute Value
Range 2500 A
Resolution 0.1 A
Accuracy 3% ±5 Digits (5 – 500 Hz)
Detailed Technical Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 - 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Flex Probe Specifications
Model i2500-10 Flex i2500-18 Flex i2500-36 Flex
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) 4.8 in (122.2 mm)
Error ±0.5 % ±0.5 % ±0.5 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
Additional Specifications
DC Current Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% ±5 digits
AC Voltage Range: 1000 V
Resolution: 0.1 V (≤600.0 V), 1 V (≤1000 V)
Accuracy: 1% ±5 digits (20 Hz to 500 Hz)
DC Voltage Range: 1000 V
Resolution: 0.1 V (≤600.0 V), 1 V (≤1000 V)
Accuracy: 1% ±5 digits
mV dc Range: 500.0 mV
Resolution: 0.1 mV
Accuracy: 1% ±5 digits

Send your inquiry directly to us

Privacy Policy China Good Quality Fluid Level Meter Supplier. Copyright © 2018-2025 Xi'an Kacise Optronics Co.,Ltd. . All Rights Reserved.