Attribute | Value |
---|---|
Product | Ultrasonic Distance Sensor |
Detection Range | 50mm~1000mm |
Transducer Frequency | 40KHZ |
Operating Voltage | 24VDC |
Limit Working Voltage | 3.6VDC~30VDC |
IP grade | IP67 |
Output | RS232/RS485 |
Sensing range | 100...1000 mm |
Unusable area | 0...100 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx.220 kHz |
Response delay | approx. 50 ms |
Indicator | Status Meaning |
---|---|
LED blue | Power-on |
LED yellow | Indication of switching state (flashing: program function object detected) |
LED red | Permanently red: Error Flashing: program function, object not detected |
Operating voltage UB | 15...30 V DC, ripple 10%SS |
No-load supply current I0 | ≤ 45 mA |
Input type | 1 TEACH-IN input |
Operating range | A1: -UB...+1 V, A2: +6 V...+UB |
Input impedance | > 4.7 kΩ |
TEACH-IN program pulse | ≥ 1 s |
Output type | 1 switch output E4, NPN NO/NC, programmable |
Rated operating current Ie | 200 mA, short-circuit/overload protected |
Default setting | Switching point A1:70mm, Switching point A2: 800mm |
Voltage drop | ≤ 2.5 V |
Repeat accuracy | ≤1 % |
Switching frequency f | ≤ 13 Hz |
Range hysteresis H | 2 % of the set operating distance |
Temperature influence | ±1.5% of full-scale value |
Ambient temperature | -25...70℃(248...343K) |
Storage temperature | -40...85℃(233...358K) |
Connection | V1 connector(M12×1),4-pin |
Protection degree | IP67 |
Material Housing | Brass, nickel-plated |
Transducer | Epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input for at least 1 second. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure.
Switching points can only be adjusted within 5 minutes after power-on. To change settings, the system must be restarted.
Mode | Procedure |
---|---|
TEACH-IN window mode, normally-open function | 1. Set target to near switching point 2. TEACH-IN switching point A1 with - UB 3. Set target to far switching point 4. TEACH-IN switching point A2 with + UB |
TEACH-IN window mode, normally-closed function | 1. Set target to far switching point 2. TEACH-IN switching point A2 with - UB 3. Set target to near switching point 4. TEACH-IN switching point A1 with + UB |
TEACH-IN switching point, normally-open function | 1. Set target to near switching point 2. TEACH-IN switching point A1 with - UB 3. Cover sensor or remove objects 4. TEACH-IN switching point A2 with + UB |
TEACH-IN switching point, normally-closed function | 1. Cover sensor or remove objects 2. TEACH-IN switching point A2 with - UB 3. Set target to near switching point 4. TEACH-IN switching point A1 with + UB |
Operating Mode | Red LED | Yellow LED |
---|---|---|
TEACH-IN switching point Object detected | off | flashes |
No object detected | flashes | off |
Object uncertain (TEACH-IN invalid) | On | off |
Normal operation | off | Switching state |
Fault | on | Previous state |
When installing the sensor in environments below 0℃, proper protective measures must be implemented. For direct mounting in through holes using steel nuts, the sensor should be fixed at the middle of the housing thread.