Send Message
Home ProductsFluid Level Meter

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage

  • Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage
  • Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage
Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage
Product Details:
Place of Origin: China (Mainland)
Brand Name: Kacise
Certification: certificate of explosion-proof,
Model Number: M18 KUS1000
Payment & Shipping Terms:
Minimum Order Quantity: 0-100
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time: 5-8 work days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Contact Now
Detailed Product Description
Product: Ultrasonic Distance Sensor Detection Range: 50mm~1000mm
Transducer Frequency: 40KHZ Operating Voltage: 24VDC
Limit Working Voltage: 3.6VDC~30VDC IP Grade: IP67
High Light:

ultrasonic level transmitter

,

ultrasonic liquid level sensor

40KHZ Frequency Ultrasonic Distance level Sensor 50mm - 1000mm Detection Range

1. Parameter

General specifications

Sensing range 100... 1000 mm
Adjustment range  
Unusable area 0 ... 100 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx.220 kHz
Response delay approx. 50 ms

 

Indicators/operating means

LED blue power-on

 

LED yellow

indication of the switching state

flashing: program function object detected

 

LED red

permanently red: Error Red,flashing:program function,object not detected

Electrical specifications

Operating voltage UB 15 ... 30 V DC , ripple 10 %SS
No-load supply current I0 ≤ 45 mA

Input

Input type 1 TEACH-IN input

operating range A1: -UB ... +1 V, operating range A2: +6 V ...

+UB

input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s

Output

Output type 1 switch output E4, NPN NO/NC,programmable
Rated operating current Ie 200 mA , short-circuit/overload protected
Default setting Switching point A1:70mm Switching point A2: 800mm
Voltage drop ≤ 2.5 V
Repeat accuracy ≤1 %
Switching frequency f ≤ 13 Hz
Range hysteresis H 2 % of the set operating distance
Temperature influence ±1.5% of full-scale value

Ambient conditions

Ambient temperature -25…70℃(248...343K)
Storage temperature -40…85℃(233...358K)

Mechanical specifications

Connection V1 connector(M12×1),4-pin
Protection degree IP67
Material Housing brass, nickel-plated
Transducer

epoxy resin/hollow glass sphere mixture;

foam polyurethane, cover PBT

 

 

2. Dimensions

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage 0

3. Electronic interface and signals definition

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage 1Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage 2


4. Description of Sensor Functions

Adjust the paramater

The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s.LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - UB,A2 with +UB. Eight different output functions can be set.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power on. If want to change the switching point, the user can only setting the request distance after power restart.

TEACH-IN window mode, normally-open function

-Set target to near switching point

-TEACH-IN switching point A1 with - UB

-Set target to far switching point

-TEACH-IN switching point A2 with + UB

TEACH-IN window mode, normally-closed function

-Set target to far switching point

-TEACH-IN switching point A2 with - UB

-Set target to near switching point

-TEACH-IN switching point A1 with + UB

TEACH-IN switching point, normally-open function

-Set target to near switching point

-TEACH-IN switching point A1 with - UB

-Cover sensor with hand or remove all objects

from sensing range

-TEACH-IN switching point A2 with + UB

TEACH-IN switching point, normally-closed function

-Cover sensor with hand or remove all

objects from sensing range

-TEACH-IN switching point A2 with - UB

-Set target to near switching point

-TEACH-IN switching point A1 with + UB

TEAC-IN large hysteresis interval, normally-open mode

-Set target to near switching point

-TEACH-IN switching point A1 with + UB

-Set target to far switching point

-TEACH-IN switching point A2 with - UB

TEAC-IN large hysteresis interval, normally-closed mode

-Set target to far switching point

-TEACH-IN switching point A2 with + UB

-Set target to near switching point

-TEACH-IN switching point A1 with - UB

TEACH-IN detection of objects presence normally open mode

-Cover sensor with hand or remove all objects from

sensing range

-TEACH-IN switching point A2 with - UB

-Cover sensor with hand or remove all objects from

sensing range

-TEACH-IN switching point A2 with + UB

TEACH-IN detection of objects presence normally closed mode

-Cover sensor with hand or remove all objects from sensing range

-TEACH-IN switching point A2 with +UB

-Cover sensor with hand or remove all objects from sensing range

-TEACH-IN switching point A2 with -UB

Default setting of switching point

A1=blind range,A2=nominal distance

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage 3

 

 

LED displays
Displays in dependence on operating mode Red LED Yellow LED

TEACH-IN switching point

Object detected

No object detected

Object uncertain(TEACH-IN invalid)

 

 

off flashes On

 

 

flashes off

off

Normal operation off Switching state
Fault on Previous state

 

 

5. Installation conditions

If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.

 

 

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage 4

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Other Products

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.