10ppm Gas Detector Sensor

Gas Detector Sensor For SF6

Gas Detector Sensor For Sulfur Hexafluoride

Place of Origin:

shanxi xi'an

Brand Name:

Kacise

Model Number:

KSS521

Contact Us
Request A Quote
Product Details
Life Span:
10 Years
Storage Temperature:
-20-80℃
Operating Temperature:
-20-60℃
Operating Humidity:
0-90%RH
Work Pressure:
0.8-1.2 Atm
Supply Voltage:
12V
Maximum Operating Current:
120mA
Detection Range (customizable):
1500ppm
Measurement Accuracy:
± 10ppm Or ±5% Truth Value
T90 Pipeline Type:
5S
T90 Pipeline Type Of Diffusion:
30S
Repeatability Of Zero:
Less Than ±50ppm
Repeatability Of Range:
Less Than ±5%.
Highlight:

10ppm Gas Detector Sensor

,

Gas Detector Sensor For SF6

,

Gas Detector Sensor For Sulfur Hexafluoride

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5 work days
Payment Terms
T/T,Western Union,MoneyGram
Supply Ability
1000 Pieces per Week
Product Description
KSS521 Infrared SF6 Gas Sensor Module
1. Overview

SF6 gas is widely used as an insulating medium and arc extinguishing gas in power equipment, especially in high-voltage circuit breakers, transformers, transformers, capacitors, arresters, fuses, etc. If leakage occurs, the pressure of the equipment is reduced and the insulation capacity is reduced; Pollute and destroy the atmospheric environment, increase the greenhouse effect; Accumulation in low-level spaces, resulting in accidents such as lack of oxygen in the brains of staff and even rapid asphyxiation; Under the influence of partial discharge, high temperature and other factors, SF6 gas will produce highly toxic decomposition substances such as SF4, SF2, SOF2, etc.
KSS521 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.5um. KSS521 adopts MEMS light source, special structure optical cavity and dual-channel detector to realize space dual optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS521 is small in size, low power consumption, and has UART, 485 (Modbus RTU, Modbus ASCII, Modbus custom optional) and single-bus digital interface, providing digital calibration zero and sensitivity functions, and providing manual calibration zero function.
KSS521 can be widely used in SF6 gas leak detection and other occasions SF6 gas concentration analysis in the power industry.

2. Technical parameters
parametersymbolminimumTypical valuesmaximumunit
Storage TemperatureTstg-20-80°C
Operating TemperatureTA-20 60°C
Operating HumidityHA0 90% RH
Work PressurePA0.8 1.2atm
Supply VoltageVs111230V
Maximum operating currentIavg100120150mA
Detection Range (customizable).Ra 1500 ppm
Measurement AccuracyAcurracy ± 10ppm or ±5% truth value %vol
T90 pipeline typePump suction 5 second
diffusion 30 second
Repeatabilityzero Less than ±50 ppm
Range Less than ±5%.
Life Span 10 year
3. Structural Dimension Drawing
Infrared SF6 Gas Sensor with ±10ppm Accuracy and 1500ppm Detection Range for 10 Years Life Span 0

KSS521 diffusion (pumping compatible) block diagram
Pump suction type: length * width * height: 61mm * 40mm * 32mm
Diffusion type: length * width * height: 61mm * 40mm * 18mm

4. Installation Instructions
  • The sensor is mounted with a positioning hole spacing of 54 mand an aperture of 3.2 mm.
  • The wiring socket spacing is 2.54 m m.
5. Matters that should be paid attention to in maintenance
  • The sensor should be calibrated regularly, not more than 3 months is recommended.
  • Do not use the sensor for a long time in an environment with a high density of dust.
  • Please use the sensor within the range of the sensor's power supply.
6. Ordering Instructions

In order to be able to purchase the specific specifications required, please provide the following information

  1. Sensor name
  2. Sensor range
  3. Sensor measurement accuracy and output mode, etc

For example, KSS521, SF6, 0-5000 ppm

7. Order Information
Order information sheet
KSS521KSS521 infrared SF6 gas sensor module
xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000Range 200ppm (default).
10000Range 10000ppm
50000Range 50000ppm
encodeThe reaction speed is divided into two types: fast and slow
SSlow (default).
Qfast
encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
CustomConfirm the baud rate before ordering
24002400bps baud rate
96009600bps baud rate
1920019200bps baud rate
3840038400bps baud rate (default)
encodeSerial port protocol
Modbus-RTUStandard Modbus-RTU protocol (default).
Modbus-ASCIIStandard Modbus-ASCII protocol
Modbus-SelfModbus private protocol
KSS521-2000-S-38400-Modbus-RTU
8. Contact Details

URL: www.kacise.com
Tel: +86-29-17719566736
Email: sales@kacise.com
Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

Appendix
ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride

Send your inquiry directly to us

Privacy Policy China Good Quality Water Quality Sensor Supplier. Copyright © 2018-2026 Xi'an Kacise Optronics Co.,Ltd. . All Rights Reserved.