logo
Home > products > Fluid Level Meter >
KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes

KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes

Strong Corrosive Foam Radar Level Sensor

Aluminum Radar Level Transmitter

Radar Corrosive Liquid Level Sensor

Place of Origin:

China

Brand Name:

Kacise

Model Number:

KLD805

Contact Us
Request A Quote
Product Details
Medium:
Strong Corrosive Liquid, Steam, Foam, High Temperature. And High Pressure
Measuring Range:
0.1m~10/20/30/60/100m
Process Connection:
Flange ≥ DN80
Process Temperature:
-40~200℃
Process Pressure:
-0.1~2.5MPa
Antenna Size:
76mm Lens Antenna (according To Flange Size)
Antenna Material:
PTFE/overall Filling
Accuracy:
±1mm
Protection Class:
IP67
Center Frequency:
80GHz
Launch Angle:
Power Supply:
DC24V/DC12~24V /AC220V
Casing:
Aluminum / Plastic / Stainless Steel
Signal Output:
4...20mA/HART Protocol/RS485 Modbus
Highlight:

Strong Corrosive Foam Radar Level Sensor

,

Aluminum Radar Level Transmitter

,

Radar Corrosive Liquid Level Sensor

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
carton
Delivery Time
5-8 work days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
100+
Product Description

KLD805 80G FM Radar Level Sensor

Principle

KLD800 series 80G radar level gauge adopts frequency modulated continuous wave (FMCW) technology. The antenna emits a high-frequency FM radar signal, and the frequency of the radar signal increases linearly. The transmitted radar signal is received by the same antenna after being reflected by the measured medium. At the same time, the frequency difference between the transmitted signal frequency and the received signal frequency is proportional to the measured distance. The collected frequency difference signal is subjected to fast Fourier transform (FFT) to obtain the spectrum of the reflected echo, and the distance to the target to be measured is calculated based on this.

 

Feature

  • Millimeter wave radar, the measurement accuracy can reach up to ±2mm, and the minimum measurement blind zone is 0.05m.
  • The smaller antenna size satisfies the measurement of more working conditions.
  • A variety of lens antennas, smaller launch angles, more concentrated energy, stronger echo signals, and higher reliability than other radar products under the same industrial and mining conditions.
  • It has stronger penetration and can be used normally in the case of adhesion and condensation.
  • The dynamic signal range is larger, and the measurement of low dielectric constant media is more stable.
  • Multiple measurement modes, radar response in fast measurement mode.

KLD805

KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 0

Medium: strong corrosive liquid, steam, foam,

high temperature. and high pressure

Measuring range: 0.1m~10/20/30/60/100m

Process connection: flange ≥ DN80

Process temperature: -40~200℃

Process pressure: -0.1~2.5MPa

Antenna size: 76mm lens antenna (according to flange size)

Antenna material: PTFE/overall filling

Accuracy: ±1mm

Protection class: IP67

Center frequency: 80GHz

Launch angle: 3°

Power supply: two-wire /DC24V

four-wire /DC12~24V

Casing: aluminum / plastic / stainless steel

Signal output: two-wire /4...20mA/HART protocol

four-wire 4...20mA/ RS485 Modbus

 

Installation

1.Flange Installation
When using flange installation, the minimum distance between the instrument and the tank wall should be 200mm.
datum plane
vessel center or axis of symmetry
KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 1                KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 2
 
2.Hoisting Installation
KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 3    KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 4
 

Installation Requirements

 

When installing the instrument, avoid installing it above the material inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.
KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 5  KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 6         KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 7

 

Under extremely complex working conditions, the instrument can work normally if there is no obstacle in the area with a radius of 20cm centered on the installation point.

 

KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 8

Installation connection diagram:

The maximum installation spool height H max depends on the installation spool diameter D and the size of the product launch angle.

Too long installation connection will affect the radar performance.

KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 9

 

 

Dimensions

Casing Dimension
Unit in mm:

KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 10

 

Product Dimension

Unit in mm:

 

Application:

KLD805 Radar Level Transmitter For Strong Corrosive Liquid Steam Foam Scenes 11

 

 

 

 

 

 

 

Send your inquiry directly to us

Privacy Policy China Good Quality Fluid Level Meter Supplier. Copyright © 2018-2025 Xi'an Kacise Optronics Co.,Ltd. . All Rights Reserved.