Place of Origin: | China |
Brand Name: | Kacise |
Certification: | CE |
Model Number: | KLD805 |
Minimum Order Quantity: | 1 |
---|---|
Price: | Negotiable |
Packaging Details: | carton |
Delivery Time: | 3-8 work days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 1000pcs per month |
Medium: | Strong Corrosive Liquid, Steam, Foam, High Temperature. And High Pressure | Measuring Range: | 0.1m~10/20/30/60/100m |
---|---|---|---|
Process Connection: | Flange ≥ DN80 | Process Temperature: | -40~200℃ |
Process Pressure: | -0.1~2.5MPa | Antenna Size: | 76mm Lens Antenna |
Antenna Material: | PTFE | Accuracy: | ±2mm For Below 35m (5mm For Range 35m-100m) |
Protection Class: | IP67 | Center Frequency: | 80GHz |
Launch Angle: | 3° | Power Supply: | DC24V / AC220V |
Casing: | Aluminum/stainless Steel | Signal Output: | 4...20mA/HART Protocol/RS485 |
High Light: | Aluminum Casing Radar Level Transmitter,76mm Lens Antenna Radar Level Sensor,High Pressure Radar Level Transmitter 80GHz |
KLD805 80GHz 76mm Lens Antenna Radar Level Transmitter for High Temperature and Pressure
Introduction
80G frequency modulation (FM) radar level transmitter—KLD805 high temperature heat dissipation type (lens antenna) is suitable for measuring liquid and solid powder and block materials under high temperature, high pressure, easy crystallization, steam, and strong dust conditions, especially in high dust and harsh temperatures Environment (+200°C) has unique advantages.
Feature
● High signal-to-noise ratio, small measurement blind zone
● High resolution, 1MM
● Higher precision, ±2MM
● Narrower emission angle, 3° antenna beam angle
● Shorter wavelength, better reflective properties on the surface of the measuring medium
Medium | strong corrosive liquid, steam, foam, high temperature. and high pressure |
Measuring range | 0.1m~10/20/30/60/100m |
Process connection | flange ≥ DN80 |
Process temperature | -40~200℃ |
Process pressure | -0.1~2.5MPa |
Antenna size | 76mm lens antenna |
Antenna material | PTFE |
Accuracy | ±2mm (range below 35m)
±5mm (range between 35m and 100m) |
Protection class | IP67 |
Center frequency | 80GHz |
Launch angle | 3° |
Power supply | two-wire /DC24V |
four-wire /DC12~24V | |
four-wire /AC220V | |
Casing | aluminum/stainless steel |
Signal output | two-wire: 4...20mA/HART protocol |
four-wire: 4...20mA/ RS485 Modbus |
Product Dimension
Unit in mm:
Installation Method
Flange installation
When using flange installation, the minimum distance between the instrument and the tank
wall should be 200mm.
① datum plane
② vessel center or axis of symmetry
Hoisting Installation
Radar level transmitter is a commonly used material measuring instrument, it can accurately measure the height of materials, and transmit the data to the control system for analysis and processing. Although the radar level transmitter has a strong tolerance, it needs special attention when used in a high temperature environment.
The high temperature environment will have a great impact on the measurement accuracy of the radar level transmitter, mainly because the high temperature will cause the material to expand, thereby affecting the measurement results of the material. Under high temperature conditions, the expansion of the material will cause deviations in the measurement of the height of the material, thereby affecting the actual consumption of the material. In addition, the high temperature environment will also have an impact on the material properties of the radar level gauge, such as reducing the life and stability of electronic components and mechanical parts.
Therefore, when the radar level transmitter needs to be used in a high temperature environment, special materials and processing methods need to be selected to ensure its stable performance. The measuring rod and antenna of the level transmitter are usually made of high temperature resistant materials such as steel and ceramics. In addition, the circuit of the level transmitter also needs to undergo special protection treatment to prevent adverse effects of high temperature on electronic components. For example, install protective covers for capacitor plates and inductors to prevent conductor corrosion caused by high temperatures.