Gas Sampling:
Diffuse Naturally
Sensor Type:
Semiconductor Sensor
Detecting Gas:
Combustible Gas & CO
Accuracy:
Combustible Gas: ±3%LEL / CO: ±50PPM
Warming Time:
3min
Alarm Set Point:
Combustible Gas: 10%LEL / CO: 100PPM
Highlight:

H3 Kitchen Gas Alarm Guardian

,

Combustible Gas Alarm Guardian

,

CO Gas Alarm Guardian

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description

Kitchen Gas Alarm Guardian: KLBH - H3

Introduction

The Kitchen Gas Alarm Guardian: KLBH - H3 is specifically designed for kitchen safety. Installed 2 - 4m horizontally from the cooker or gas source, it provides reliable gas monitoring. It can precisely detect LPG and natural gas, with different vertical installation guidelines for each. Using advanced technology, it activates alarms within 60 seconds when gas levels are abnormal. With features like automatic resumption within 30 seconds and optional 220V relay output, it ensures comprehensive kitchen gas safety

Product Features

1. Precise installation guidelines for different gas types.

2. Fast response time of within 60 seconds.

3. Automatic resumption within 30 seconds.

4. Optional 220V relay output.

5. Suitable for kitchen gas detection

Technical Parameters

Model KLBH-H3
Detecting gas Combustible gas & CO
Sensor type Semiconductor sensor
Gas Sampling Diffuse naturally
Alarm set point Combustible gas: 10%LEL / CO: 100PPM
Warming time 3min
Accuracy Combustible gas: ±3%LEL / CO: ±50PPM
Response time ≦60s
Resume automatically ≦30s
Power AC220V
Alarm current <50mA
Power Consumption <1W
Alarm Method Visual and audible
Sound level ≧70dB
Optional function 220V relay,9V pulse, relay output NO or NC