Place of Origin:
CHINA
Brand Name:
KACISE
Certification:
CE
Model Number:
KGD-WQ-509
The Engine Exhaust Particle Number Analysis System continuously measures the number concentration of solid particles in engine exhaust gas online. This system can be integrated with full-flow or partial-flow dilution systems and is designed for engine/vehicle certification testing in compliance with the latest regulations. It also supports direct exhaust gas measurement from exhaust pipes for research and development of engines or after-treatment devices.
| Parameter | Heavy-duty Vehicles: Euro VI, China VI; Non-Road Mobile Machinery: Stage V | Heavy-duty Vehicles: Euro 7 |
|---|---|---|
| Minimum Particle Size Limit (Counting Efficiency) | 23 nm (50% ± 12%) | 10 nm (65% ± 15%) |
| Minimum Particle Size Limit (Counting Efficiency) | 41 nm (>90%) | 15 nm (>90%) |
| Measurement Principle | Condensation Particle Counting | Condensation Particle Counting |
| CPC Measurement Range | 0 - 100000 #/cm³ | 0 - 100000 #/cm³ |
| CPC Measurement Precision | ≤ ±10% | ≤ ±10% |
| Primary Dilution Ratio | 10 | 10 |
| Secondary Dilution Ratio | 10-30 | 10-30 |
| Precision of Total Dilution Ratio | ≤ ±10% of the set value | ≤ ±10% of the set value |
| VPR Removal Efficiency | >99.0% (C40) | >99.0% (C40) |
| Response Time | T90 < 5s | T90 < 5s |
| Operating Environment | Ambient temperature: 5 - 35°C; Relative humidity: ≤ 80%RH | Ambient temperature: 5 - 35°C; Relative humidity: ≤ 80%RH |