KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer
Product Introduction
The KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer employs micro - flow infrared half - cell gas sensing technology. It enables simultaneous and accurate measurement of concentration changes of greenhouse gases such as CO₂, CH₄, N₂O, as well as CO gas in flue gas. The measuring range can reach as low as 200 ppm, with an accuracy of up to 1% F.S. It features strong resistance to gas cross - interference and lower drift.
Moreover, to meet the measurement requirements for high - concentration CO₂ and medium - to - high - range CO, sensor modules with Non - Dispersive Infrared (NDIR) gas sensor technology can be optionally configured for flexibility. These modules are characterized by good stability, small size, and low cost.
Product Features
One analyzer can simultaneously and continuously measure up to five gases, including CO₂, CH₄, N₂O, CO, and O₂.
For CO₂, CH₄, N₂O, and CO, the patented micro - flow infrared technology can be selected, with a measuring range as low as 200 ppm and an accuracy of up to 1% F.S.
Small drift, resistant to moisture interference, and stable for long - term use.
For medium - to - high - concentration measurement needs, dual - beam infrared sensing technology can be used to measure CO₂ and CO, allowing for flexible combinations.
It has both digital and analog signal output functions, enabling simple and convenient data management.
Technical Parameters
Parameter | Details |
Measured Components | CO₂, CH₄, N₂O, CO, O₂ |
Measurement Principle | Micro - flow NDIR: CO₂/CH₄/N₂O/CO |
Dual - beam NDIR: CO₂ (high range) and CO (medium - high range) | |
Electrochemical (ECD): O₂ | |
Measurement Range - Carbon Dioxide (CO₂) | Micro - flow: Range 0 - 500 ppm, Resolution 1 ppm |
Micro - flow: Range 0 - 20%, Resolution 0.01% | |
Dual - beam: Range 0 - 25/100%, Resolution 0.01% | |
Measurement Range - Methane (CH₄) | Range 0 - 1000 ppm, Resolution 1 ppm |
Measurement Range - Nitrous Oxide (N₂O) | Range 0 - 1000 ppm, Resolution 1 ppm |
Measurement Range - Carbon Monoxide (CO) | Micro - flow: Range 0 - 200/5000 ppm, Resolution 1 ppm |
Dual - beam: Range 0 - 1/5%, Resolution 0.001% | |
Measurement Range - Oxygen (O₂) | Range 0 - 25%, Resolution 0.01% |
Measurement Accuracy | Micro - flow NDIR for CO₂/CH₄/N₂O/CO: ±1% F.S. |
Dual - beam NDIR for CO₂/CO: ±2% F.S. | |
ECD for O₂: ±2% F.S. | |
Repeatability | ≤±1% |
Response Time | T90 < 25s |
Optimal Flow Rate | (0.7 - 1.2) L/min |
Inlet Gas Pressure | (2 - 50) Kpa |
Sample Gas Requirements | Dewatered (no condensation); Dust - filtered (filtration accuracy < 1μm) |
Signal Output | RS - 485/RS - 232, (4 - 20)mA |
Power Supply | 100 - 240VAC, 3000W (maximum heating power)/100W (stable power) |
Diagnostic Function | Has a self - diagnostic function to check the sensor status |