KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer
Product Introduction
The KGD - YQ - 501 Greenhouse Gas (CO₂/CH₄/N₂O) Emission Analyzer employs micro - flow infrared half - cell gas sensing technology. It enables simultaneous and accurate measurement of concentration changes of greenhouse gases such as CO₂, CH₄, N₂O, as well as CO gas in flue gas. The measuring range can reach as low as 200 ppm, with an accuracy of up to 1% F.S. It features strong resistance to gas cross - interference and lower drift.
Moreover, to meet the measurement requirements for high - concentration CO₂ and medium - to - high - range CO, sensor modules with Non - Dispersive Infrared (NDIR) gas sensor technology can be optionally configured for flexibility. These modules are characterized by good stability, small size, and low cost.
![]()
Product Features
One analyzer can simultaneously and continuously measure up to five gases, including CO₂, CH₄, N₂O, CO, and O₂.
For CO₂, CH₄, N₂O, and CO, the patented micro - flow infrared technology can be selected, with a measuring range as low as 200 ppm and an accuracy of up to 1% F.S.
Small drift, resistant to moisture interference, and stable for long - term use.
For medium - to - high - concentration measurement needs, dual - beam infrared sensing technology can be used to measure CO₂ and CO, allowing for flexible combinations.
It has both digital and analog signal output functions, enabling simple and convenient data management.
Technical Parameters
| Parameter | Details |
| Measured Components | CO₂, CH₄, N₂O, CO, O₂ |
| Measurement Principle | Micro - flow NDIR: CO₂/CH₄/N₂O/CO |
| Dual - beam NDIR: CO₂ (high range) and CO (medium - high range) | |
| Electrochemical (ECD): O₂ | |
| Measurement Range - Carbon Dioxide (CO₂) | Micro - flow: Range 0 - 500 ppm, Resolution 1 ppm |
| Micro - flow: Range 0 - 20%, Resolution 0.01% | |
| Dual - beam: Range 0 - 25/100%, Resolution 0.01% | |
| Measurement Range - Methane (CH₄) | Range 0 - 1000 ppm, Resolution 1 ppm |
| Measurement Range - Nitrous Oxide (N₂O) | Range 0 - 1000 ppm, Resolution 1 ppm |
| Measurement Range - Carbon Monoxide (CO) | Micro - flow: Range 0 - 200/5000 ppm, Resolution 1 ppm |
| Dual - beam: Range 0 - 1/5%, Resolution 0.001% | |
| Measurement Range - Oxygen (O₂) | Range 0 - 25%, Resolution 0.01% |
| Measurement Accuracy | Micro - flow NDIR for CO₂/CH₄/N₂O/CO: ±1% F.S. |
| Dual - beam NDIR for CO₂/CO: ±2% F.S. | |
| ECD for O₂: ±2% F.S. | |
| Repeatability | ≤±1% |
| Response Time | T90 < 25s |
| Optimal Flow Rate | (0.7 - 1.2) L/min |
| Inlet Gas Pressure | (2 - 50) Kpa |
| Sample Gas Requirements | Dewatered (no condensation); Dust - filtered (filtration accuracy < 1μm) |
| Signal Output | RS - 485/RS - 232, (4 - 20)mA |
| Power Supply | 100 - 240VAC, 3000W (maximum heating power)/100W (stable power) |
| Diagnostic Function | Has a self - diagnostic function to check the sensor status |