Place of Origin: | CHINA |
Brand Name: | KACISE |
Certification: | CE |
Model Number: | KLD 26GHz series |
Minimum Order Quantity: | 0-100 |
---|---|
Price: | 200-800 |
Delivery Time: | 5-8 working days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal |
Supply Ability: | 10000pcs/month |
Frequency: | 26GHz | Output: | 4...20mA/HART, RS485/Modbus |
---|---|---|---|
Explosion-proof: | Exia IIC T6 Ga/Exd Ia IIC T6 Gb | Protection: | IP67/IP65 |
High Light: | ultrasonic fluid level sensor,ultrasonic level transmitter |
KLD 26GHz Series High Frequency 4-20mA HART RS485 Modbus Radar Level Meter Powder Level Meter
This series of radar level meter adopts 26G high frequency radar sensor. The maximum measurement range can be up to 80 meters. The newly developped microprocessor achieves much faster signal analysis and process, making sure that the unit can be used for the measurement of complicated environment such as reactor and solid silo.
1. Working Principle:
The radar antenna transmites narrow microwave pulse which will be reflected back when reaching the surface of the medium tested and then received again by the antenna system. The signals shall be transmitted to the electric circuit and then converted into level signals. As the transmission speed of microwave is so fast, the time used for the microwave transmission to the surface of the medium tested and then reflected back is almost 0.
2. Technical Features:
3. Technical Specification and Model Selections:
11
Housing | ||
Seal between housing and housing cover | Silicone rubber | |
Housing window | Polycarbonate | |
The ground terminal | Stainless steel | |
The power supply voltage | ||
Two wire | The standard type | (16 ~ 26) V DC |
Intrinsically safe | (21.6 ~ 26.4) V DC | |
Power dissipation | max 22.5mA / 1W | |
Allowable ripple | - <100Hz | Uss<lV |
- (100~100K) Hz | Uss<l0mV | |
The cable parameters | ||
Cable entrance / plug | 1 M20xl.5 cable entrance | |
1 blind plug | ||
Terminal | Conductor cross section 1.0mm² | |
Output | The output signal | (4 ~ 20) mA |
Communication protocol | HART | |
Resolution | 1.6μA | |
Fault signal
|
Constant current output; 20. 5mA, 22mA, 3.9mA |
|
The integral time | (0 ~ 50) s, adjustable | |
Blind zone | the ends of the antenna | |
Max. measuring range | 80m | |
Microwave frequency | 26GHz | |
Communication interface | HART communication protocol | |
The measurement interval | about 1 second (depending on the parameter settings) | |
Adjustment time | about 1 second (depending on the parameter settings) | |
Display resolution | 1 mm | |
Working storage and transportation temperature | (-40~100) ℃ | |
Process temperature (the temperature of the antenna part) | (-40~250)℃ | |
Pressure | Max.4MPa | |
Seismic | Mechanical vibration l0m/s², (10 ~ 150) Hz |