logo
Home > Products > Fluid Level Meter >
10m Range Ultrasonic Level Sensor with 4-20mA Output for Automatically Controlling Water Level Meter

10m Range Ultrasonic Level Sensor with 4-20mA Output for Automatically Controlling Water Level Meter

10m Ultrasonic Level Sensor

Automatically Controls Switch Ultrasonic Level Sensor

20mA Water Level Meter

Place of Origin:

CHINA

Brand Name:

KACISE

Certification:

CE

Model Number:

KUM-A

Contact Us
Request A Quote
Product Details
Product Type:
Integrated
Power Supply:
24 VDC Optional: 220V AC+15% 50Hz
Display:
English Led Display
Cable Probe:
No
Digital Output:
RS485
Resolution:
3mm Or 0.1%
Product Name:
Digital Integrated Ultrasonic Level Meter Non-Contact Level Sensor Level Mesurement Used In Municipal Project
Apply:
Liquid Solid
Highlight:

10m Ultrasonic Level Sensor

,

Automatically Controls Switch Ultrasonic Level Sensor

,

20mA Water Level Meter

Payment & Shipping Terms
Minimum Order Quantity
1PCS
Price
USD157 to USD610 per pc
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
T/T,Western Union,MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
Product Description
10m Ultrasonic Level Sensor 4 - 20mA Automatically Controls Switch Water Level Meter

Note: Range information is very important
The 10m Ultrasonic Level Sensor is a remarkable device. It features a 4 - 20mA output and can automatically control the switch of the water level meter. With a maximum sensing range of 10 meters, it accurately measures water levels, making it highly suitable for various water level monitoring and control applications.

Technical Features:
  • Non-contact, can be used in various applications;
  • Various types of probes are available to meet the requirements of various applications.
  • High accuracy: 0.5%, 1%
  • English LED Display
Structure:

10m Range Ultrasonic Level Sensor with 4-20mA Output for Automatically Controlling Water Level Meter 0

Technical Specifications:
SpecsValue
Pressure Voltage5m, 10m, 15m, 20m, 30m, 40m, 50m, 60m
Accuracy0.5%, 1.0%
DisplayLCD
Ambient TemperatureDisplay instrument-20~+60℃
transducer-20~+80℃
Mediumliquid and solid
Analog Output4-20mA
Digital OutputRS485, RS232 (both are optional)
Power Supply24Vdc
Protection GradeDisplay instrument IP65,transducer IP68
Probe TypePVDF, aluminum alloy, ABS, stainless steel 316L, teflon, titanium alloy
Model Selection:
KUM-A
Measurement Range
A5m
B10m
C15m
D20m
E30m
F40m
G50m
H60m
Output Signal
A4-20mA
Accuracy
0.50.5%
1.01%
Power Supply
A24Vdc
B11~30Vdc
Probe Type
APVDF
BAluminum alloy
CABS
DStainless steel 316L
ETeflon
FTitanium alloy
Applications and Installations:
  • Distance measurement
  • Depth measurement

10m Range Ultrasonic Level Sensor with 4-20mA Output for Automatically Controlling Water Level Meter 1
10m Range Ultrasonic Level Sensor with 4-20mA Output for Automatically Controlling Water Level Meter 2
10m Range Ultrasonic Level Sensor with 4-20mA Output for Automatically Controlling Water Level Meter 3

Common problems and solutions guidance during installation
Fault descriptioncause of issueSolution
Meter does not display, does not workWrong power supply Wrong wiringCheck whether the DC24v power supply is correct Check whether the wiring is correct
The instrument has display, does not work 1. The level gauge is not aligned with the liquid level or material level
2. The liquid level fluctuates greatly
3. The material surface is extremely uneven
4. The liquid surface has a thicker foam layer
5. The bottom of the container is not flat after the liquid is emptied and the material is emptied
6. Out of measurement range
1. Adjust the alignment direction of the level gauge, and use a spirit level to calibrate and add a plastic tube to the container
2. Use a level gauge with a larger range
3. Use a level gauge with a larger range or other measurement methods
4. Naturally resume work after adding liquid or material
5. Use a level gauge with a larger range
The instrument display is unstable or the measured value has a large deviation 1. The material level enters the blind spot
2. The distance measurement value is greater than the installation height
3. There is strong electromagnetic interference
4. Objects that block sound waves
5. A metal flange is prepared on the level meter
6. The emitting surface or side of the probe is in contact with metal
1. Elevate the level meter or prevent the level from being too high
2. Modify the installation height to the correct value
3. The instrument must be connected to the ground, and shield the level gauge
4. Change the installation position or add plastic pipes
5. Switch to plastic flanges
6. Use rubber pads to isolate from metal

For the container with the installation port or the probe placed in the round pipe, the length of the flange connection of the 4m, 6m and 8m type level gauge container should be less than 400mm, and the length of the 12m level gauge container should be less than 400mm.
150mm, 15m, 20m, 30m level sensor probes should protrude from the installation port.

Send your inquiry directly to us

Privacy Policy China Good Quality Water Quality Sensor Supplier. Copyright © 2018-2026 Xi'an Kacise Optronics Co.,Ltd. . All Rights Reserved.