Place of Origin:
china
Brand Name:
KACISE
Certification:
CE
Model Number:
KDI Series
KACISE's KDI Series Display Controller is highly compatible with standard indexing temperature sensors. It can work with a wide range of sensors, such as different types of thermocouples and thermal resistances. This compatibility makes it suitable for various temperature measurement requirements. Whether for high - temperature industrial processes or precise laboratory temperature control, this controller can accurately measure and display temperature values, all under KACISE's strict quality standards.
| Input Signal | Indexing No. |
Resolution | Sensor | Range |
| B | 1 | Platinum30-platinum6 rhodium | 400~1800℃ | |
| S | 1 | Platinum10-platinum | 0~1600℃ | |
| K | 1 | Nickel chromium-nickel silicon | 0~1300℃ | |
| E | 1 | Nickel chromium-constantan | 0~1000℃ | |
| J | 1 | Iron-constantan | 0~1200℃ | |
| T | 0.1 | Copper-constantan | -199.9~3200℃ | |
| Wre | 1 | Tungsten3-tungsten25 | 0~2300℃ | |
| Pt100 | 1 | Platinum thermal resistance R0 = 100Ω | -199~650℃ | |
| Pt100 | 0.1 | Platinum thermal resistance R0= 100Ω | -199.9~320.0℃ | |
| Cu50 | 0.1 | Copper thermal resistance R0= 50Ω | -50.0~150.0℃ |
| Input Signal | Standard Signal Range |
Input Resistance | Matching Transmitter | Measuring Range |
|
various mV signal 0~10mA 4~20mA 0~5V 1~5V 30~350Ω |
≥10MΩ ≤250Ω ≤250Ω ≥250KΩ ≥250KΩ |
hall transmitter compatible with DDZ-II type instrument compatible with DDZ-III type instrument compatible with DDZ-II type instrument compatible with DDZ-III type instrument compatible with remote pressure resistors |
set according to user needs. range: -1999~9999 |
| Input Signal | Analog |
Resistance: standard thermal resistance (remote pressure resistance such as Pt100, Cu50) Galvanic couples: standard thermocouples ( B, S, K, E, J, T, WRe, etc.) Current: 0~10mA, 4~20mA, 0~20mA, etc. (Input impedance ≤250Ω) Voltage: 0~5V, 1~5V, etc.(Input impedance ≥250Ω) |
| Measuring Range | -1999~9999 | |
| Accuracy | 0.2% FS ±1 or 0.5% FS ±1 | |
| Resolution | 1, 0.1, 0.01 or 0.001 | |
| Temperature Compensation | 0~50 | |
| Display Method |
-19999~9999 measured value display -19999~9999 set value display 0~100% measured value light column display LED operating status display |
|
| Light Column Accuracy | The light column display accuracy is 1% | |
| Control Method | Position ON / OFF with backlash | |
| Output Signal | Analog output |
DC 0-5V (load capacity ≤250Ω) DC 1~5V (load capacity ≤250Ω) DC 0~10mA (load capacity ≤750Ω) DC 4~20mA (load capacity ≤500Ω) |
| Switch output |
Relay control output - Relay ON/OFF with backlash Contact capacity: AC220V/3A; DC24V/6A (resistive load) Controllable silicon output-SCR (controllable zero-crossing pulse), can trigger controllable silicon: 400V/100A Solid state relay output - SSR (solid state relay control signal) output, 6 ~ 24 / 30mA (voltage cannot be adjusted) |
|
| Communication output |
Interface mode - Standard serial two-way communication interface: RS-485, RS-232C, RS-422, etc. | |
| Feed output | DC24V, load capacity ≤30mA | |
| control method |
Optional 1~4 limit control, LED indication. The control mode is the relay ON/OFF with backlash (user can set it freely) |
|
| control accuracy | ±1 | |
| Alarm mode | You can select 1~4 limit alarm, LED indication. The control mode is the relay ON/OFF with backlash (user can set it freely) | |
| Alarm accuracy | ±1 | |
| Temperature compensation | 0~5 0°C digital temperature automatic compensation | |
| Parameter setting |
|
|
| Protection method |
|
|
| Online communication | The communication protocol is a two-wire system, a three-wire system or a four-wire system (e.g. RS485, RS232C, RS422, etc. ) can also be specially requested by the user. The baud rate of 300 to 9 6 0 0 b p s can be set freely by the internal parameters of the instrument. The interface and the main unit are separated by photo-electricity, and the communication distance can reach 1.2 km. The system adopts the master-slave communication mode. The whole control loop only needs one two (three, four) core cable, which can realize communication with the host computer. The upper computer can call the device number set by the user, and call the scene of each instrument at any time. Data, and can be used to set internal parameters of the instrument. Equipped with data collector and industrial control software, it can realize online communication between multiple instruments and one or more microcomputers. | |
| Use environment |
|
|
| Power Supply |
Normal type :
Special type:
|
|
| Power consumption |
|
|
| Weight | 420g (AC220V linear power supply) | |